Inspections for the day of: Thursday, September 27, 2018.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-02986 Final9/27/20189/27/20189/28/2018 6:42:24 AMPCANC
Kelly Phone #: ###-####
ELE18-02986 Final9/27/20189/27/20189/27/2018 3:43:58 PMPFAIL
Kelly Phone #: ###-#### 210.11C2 and C3. Laundry room and Bath shall have 20Amp Dedicated circuits. ( Washer was moved from kitchen closet to back room. Needs updated circuitry and removed from bath circuit.) 314.20 Boxes set back more than 1/4in shall have extension rings. (All Devices in tile) 406.12 All dwelling unit receps shall be Tamper proof. (Dining and Front room)
ELE18-03490 Electrical Rough-In9/27/20189/27/20189/27/2018 2:34:00 PMPPASS
Need ceiling grid rough-in cover
Phone #: ###-#### Inspection requested via web by Brad Girard Conferance room and 2 offices only rest is exhisting. ok to cover
ELE18-03678 Rough-In Permanent Service9/27/20189/27/20189/27/2018 2:19:37 PMPPASS
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
ELE18-03632 Temporary Service9/27/20189/27/20189/27/2018 1:33:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Corrections made t/s u/g n ok
ELE18-03575 Rough-In Permanent Service9/27/20189/27/20189/27/2018 1:31:51 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Corrections made rough in ok p/s u/g n ok
ELE18-03635 Permanent Service9/24/20189/27/20189/27/2018 1:01:25 PMPPASS
There will be guys there working. If you have any questions please feel free to contact Fred ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Check sub panel at rough in for seperation of grounds. p/s o/h rec ok
ELE18-03088 Electrical Rough-In9/27/20189/27/20189/27/2018 12:33:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Ceiling rough in main Dining area ok to cover
ELE18-02836 Rough-In Permanent Service9/27/20189/27/20189/27/2018 11:33:30 AMPPASS
It is open. If you have any questions, please call Tony at ###-####. Thank You Phone #: ###-#### Inspection requested via web by Clayton Morgan Check house UFER connection at final. UFER is directly behind House panel. (NEC 250.32) Garage and house. Rough in ok.. p/s o/h n ok
ELE18-02836 Electrical Rough-In9/27/20189/27/20189/27/2018 11:31:32 AMPCANC
It is open. If you have any questions, please call Tony at ###-####. Thank You Phone #: ###-#### Inspection requested via web by Clayton Morgan
ELE18-03640 Rough-In Permanent Service9/26/20189/27/20189/27/2018 11:31:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in ok p/s u/g n ok
ELE18-03568 Final9/26/20189/27/20189/27/2018 10:39:01 AMANH
Phone #: ###-#### Inspection requested via web by Jesse Fuentes No access. Nobody home.
ELE18-03222 Final9/26/20189/27/20189/27/2018 9:49:42 AMAPASS
Access is best through either side gate.
2 levels added on rear of house. Phone #: ###-#### Inspection requested via web by David McClellan Final ok
ELE18-03375 Electrical Rough-In9/26/20189/27/20189/27/2018 9:29:31 AMAPASS
Wall rough in inspection for B17C Executive Suites
Contact Pierce Bouge
Thank you Phone #: ###-#### Inspection requested via web by Tom Betty Discussed Requirments of 210.71B1 and 2. Furniture receps will make up quantity needed in Large meeting room. Will need 3 floor receps in Large room and 1 in smaller room. Walls only ok to cover