MEC18-04628
| Final | 9/26/2018 | 9/27/2018 | 9/27/2018 3:55:57 PM | P | PASS |
|
|
Please call customer (Nancy Williams) prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace only co ok
|
MEC18-04362
| Rough-in | 9/27/2018 | 9/27/2018 | 9/27/2018 3:16:42 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok- need to make sure to place unit number in notes 5146 surprise way has 4 locations
|
MEC18-04425
| Conference | 9/27/2018 | 9/27/2018 | 9/27/2018 3:14:35 PM | P | DONE |
|
|
smoke detector installation- talked with general about leaving the smoke detector in place and testing air requirments through the smoke detectors to make sure they meet manufactures specs
|
MEC18-04655
| Final | 9/27/2018 | 9/27/2018 | 9/27/2018 2:11:20 PM | P | NH |
|
|
Phone #: ###-#### Inspection requested via web by Benny Arreola- no access
|
MEC18-04671
| Rough-in | 9/26/2018 | 9/27/2018 | 9/27/2018 12:00:37 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello- R/I ok
|
MEC18-04671
| Pressure Test | 9/26/2018 | 9/27/2018 | 9/27/2018 11:59:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello- 20lb gas pressure test ok- 5lb flue pressure test ok
|
MEC18-04688
| Pressure Test | 9/27/2018 | 9/27/2018 | 9/27/2018 11:02:13 AM | P | CANC |
|
|
Inspection requested via web by Floyd Floyd Peek- cancelled per conversation with contractor not ready
|
MEC18-04688
| Rough-in | 9/27/2018 | 9/27/2018 | 9/27/2018 11:01:56 AM | P | CANC |
|
|
Inspection requested via web by Floyd Floyd Peek- cancelled per conversation with contractor not ready
|
MEC18-04579
| Final | 9/24/2018 | 9/27/2018 | 9/27/2018 10:10:42 AM | A | FAIL |
|
|
please call home owner 20 mins ahead- ###-#### MElissa Inspection requested via web by Benny Arreola- need to install sediment trap after shut off valve on gas line at furnace- need to install co detectors upstairs- power conduit for A/C needs to be weather tight- lineset at outdoor unit needs to be UV protected with UV tape or UV paint
|
MEC18-04666
| Final | 9/26/2018 | 9/27/2018 | 9/27/2018 9:51:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Xanti Berria- furnace ac coil co ok
|
MEC18-03463
| Final | 9/26/2018 | 9/27/2018 | 9/27/2018 8:57:33 AM | A | PASS |
|
|
Please call customer when on your way please. She said she will be home if someone calls. Thanks so much and I apologize for any misunderstandings. Phone #: ###-#### Inspection requested via web by Dan McFate - co ok- final ok
|
MEC17-04577
| Mec-Aging Inspection | 9/27/2018 | 9/27/2018 | 9/27/2018 8:36:48 AM | | PASS |
|
|
|
MEC18-04225
| Final | 9/25/2018 | 9/27/2018 | 9/27/2018 8:36:30 AM | A | PASS |
|
|
PLEASE CALL TENANT STEVE @ # LISTED WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- furnace only co ok
|
MEC18-02163
| Final | 9/26/2018 | 9/27/2018 | 9/27/2018 8:17:08 AM | A | PASS |
|
|
GARAGE CODE 1808 Phone #: ###-#### Inspection requested via web by Krista Boss - dryer vent sealed- air balance onsite ok- final ok
|