BLD18-01726
| BLD-Aging Inspection | 9/27/2019 | 9/27/2019 | 9/27/2019 5:29:37 PM | | PASS |
|
|
Expires: 11/12/19
|
BLD19-03105
| BLD-Wall Bracing | 9/27/2019 | 9/27/2019 | 9/27/2019 5:28:53 PM | P | PASS |
|
|
Dan Phone #: ###-####
|
BLD19-01949
| BLD-Framing/Rough-in | 9/27/2019 | 9/27/2019 | 9/27/2019 5:04:09 PM | P | FAIL |
|
|
Call half hour before // Doyle Phone #: ###-####//1 hr ceiling does not meet details on plans//submit plan mod for changes in fire rated ceiling//verify penetrations for cans in rated ceiling//
|
BLD19-00093
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 4:42:29 PM | P | NR |
|
|
Charity-call prior to meet for access Phone #: ###-####//need plumbing final//all other areas ok//
|
BLD19-02660
| BLD-Ceiling Grid Inspection | 9/27/2019 | 9/27/2019 | 9/27/2019 4:13:42 PM | P | PASS |
|
|
firecaulk complete//grid ok//
|
BLD18-02107
| BLD-Conference | 9/26/2019 | 9/27/2019 | 9/27/2019 3:54:07 PM | P | DONE |
|
|
If we can meet after 3:30 that would be great. Please call or text me 15min before you get to my house and I will meet you there. Thank you! Phone #: ###-#### Inspection requested via web by Daniel Grover
|
BLD19-03315
| BLD-Footing | 9/26/2019 | 9/27/2019 | 9/27/2019 3:35:57 PM | P | PASS |
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru//cancel per Ricardo//
|
BLD19-01838
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 2:55:16 PM | P | PART |
|
|
Carl Phone #: ###-####//phase 1 TCO approved//
|
BLD19-02660
| BLD-Ceiling Grid Inspection | 9/27/2019 | 9/27/2019 | 9/27/2019 2:30:08 PM | P | NR |
|
|
Tony Phone #: ###-####//need to firecaulk all penetrations through 2 hour wall//
|
BLD19-03727
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 2:08:24 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joseph knight//need plumbing permits and electrical permits and inspections for remodel//
|
BLD17-01642
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:54:28 PM | P | CANC |
|
|
Brandy Phone #: ###-####//cannot find address//correct address and call for re-inspection//
|
BLD19-02288
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:49:53 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//need to add handrail to back steps//handrail on front steps to high at front//38'' max height//
|
BLD17-03869
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:43:30 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//correction notice posted//need to add handrails//maintain 1.5 inch clearance on sides of handrails//
|
BLD19-02289
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:36:10 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//need handrail on rear steps//need electrical final(not linked to permit)//correction notice postede//
|
BLD18-00367
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:25:39 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//guard at steps to low//handrail too low//correction notice posted//
|
BLD17-04226
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:19:17 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//handrail at back steps is still over 38" max height//
|
BLD19-02290
| BLD-Final | 9/27/2019 | 9/27/2019 | 9/27/2019 1:08:02 PM | P | FAIL |
|
|
Brandy Phone #: ###-####//back porch handrail needs to return back into guard//
|
BLD19-02972
| BLD-Wall Bracing | 9/26/2019 | 9/27/2019 | 9/27/2019 12:52:17 PM | P | FAIL |
|
|
shear // Vedad Phone #: ###-####//need engineering for tall walls//add straps to header at portal frame//correction notice posted//
|
BLD18-03443
| BLD-Energy code compliance | 9/27/2019 | 9/27/2019 | 9/27/2019 12:42:48 PM | P | PASS |
|
|
|
BLD18-03443
| BLD-Framing/Rough-in | 9/26/2019 | 9/27/2019 | 9/27/2019 12:41:56 PM | P | CANC |
|
|
Greg Phone #: ###-####
|
BLD19-02859
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 12:28:45 PM | P | PASS |
|
|
Patrick Phone #: ###-####//final complete//
|
BLD19-02859
| DOC - Permit Finaled | 9/27/2019 | 9/27/2019 | 9/27/2019 12:28:27 PM | P | PASS |
|
|
|
BLD19-03537
| BLD-Final | 9/23/2019 | 9/27/2019 | 9/27/2019 12:19:01 PM | A | PASS |
|
|
Inspection requested via web by Hans Weikl//roof appears to be installed within code requirements//
|
BLD19-03537
| DOC - Permit Finaled | 9/27/2019 | 9/27/2019 | 9/27/2019 12:18:30 PM | P | PASS |
|
|
|
BLD19-03194
| BLD-Framing/Rough-in | 9/27/2019 | 9/27/2019 | 9/27/2019 12:09:33 PM | P | PASS |
|
|
Call 20 mins ahead-Tim Phone #: ###-####//ok for wall cover only//call for grid inspection//
|
BLD19-02546
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 11:57:25 AM | A | PASS |
|
|
Need inspection ASAP in morning please...... and thank you! have a great weekend! Phone #: ###-#### Inspection requested via web by Candyce Moss
|
BLD19-02546
| DOC - Permit Finaled | 9/27/2019 | 9/27/2019 | 9/27/2019 11:56:46 AM | P | PASS |
|
|
|
BLD19-03649
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 11:44:12 AM | A | PASS |
|
|
Adam Phone #: ###-####//no changes to existing//
|
BLD19-03267
| BLD-Framing/Rough-in | 9/26/2019 | 9/27/2019 | 9/27/2019 11:20:43 AM | A | NR |
|
|
call ahead please- John Phone #: ###-####//window ok//need plumbing and electrial rough completed//
|
BLD19-03311
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 11:05:17 AM | A | PASS |
|
|
Brian Prussia: ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting
|
BLD19-03311
| DOC - Permit Finaled | 9/27/2019 | 9/27/2019 | 9/27/2019 11:05:08 AM | P | PASS |
|
|
|
BLD19-01045
| BLD-Other | 9/26/2019 | 9/27/2019 | 9/27/2019 10:50:26 AM | A | PASS |
|
|
fire wall // Tony Phone #: ###-####//all penetrations sealed//
|
BLD18-03200
| BLD-Final | 9/26/2019 | 9/27/2019 | 9/27/2019 10:50:01 AM | A | PASS |
|
|
Tony Phone #: ###-####//final complete per plans//pending all special inspections are complete and final//
|
BLD19-02010
| BLD-Wall Bracing | 9/27/2019 | 9/27/2019 | 9/27/2019 10:02:52 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk//sthds in wrong locations//framing and nailing needs address at portal frames//window added in shear location at front entry//2 hr wall does not reflect plans//
|
BLD19-02007
| BLD-Wall Bracing | 9/27/2019 | 9/27/2019 | 9/27/2019 10:01:43 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Carl Funk//need to address nailing and blocking at portal frames//sthds in wrong locations//windows added in shear location at front entry//2 hr wall contruction does not match plans//
|
BLD19-02600
| BLD-Framing/Rough-in | 9/27/2019 | 9/27/2019 | 9/27/2019 9:26:14 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Stover//need rough ins for mechanical completed and inspected prior to framing//
|
BLD19-02238
| BLD-Framing/Rough-in | 9/26/2019 | 9/27/2019 | 9/27/2019 9:24:47 AM | A | PART |
|
|
Chris Phone #: ###-####//ok to cover bathroom walls only//need shearwalls to reflect plans--anchoring, posts,mechanical connections and shear nailing//need mechanical inspection for ceilings//
|
BLD19-01619
| BLD-Wall Bracing | 9/26/2019 | 9/27/2019 | 9/27/2019 8:51:05 AM | A | PASS |
|
|
Dean Phone #: ###-####//ok per plans//
|
BLD19-01949
| BLD-Framing/Rough-in | 9/26/2019 | 9/27/2019 | 9/27/2019 8:24:53 AM | A | FAIL |
|
|
Doel Phone #: ###-####//no framers onsite//appears to be front entry cover--framing is not visible as framing has already been covered//call for re-inspection//
|