Inspections for the day of: Monday, September 28, 2009.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-00324 Final9/28/20099/28/20099/28/2009 3:58:52 PMPPASS
ok to final, no esc this project
ELE09-00324 Electrical Rough-In9/28/20099/28/20099/28/2009 3:57:26 PMPCANC
John Phone #: ###-#### wrong permit called in, see ELE07-02961, no esc this project
ELE09-00309 Final9/28/20099/28/20099/28/2009 3:55:40 PMPPASS
adam Phone #: ###-#### called contractor, ok to final, no esc this project
ELE07-02961 Electrical Rough-In9/28/20099/28/20099/28/2009 2:59:28 PMPFAIL
corrections not all made, created others, will call back after install new box for broken cable clamp, use looms for wiring support, lengthen short ground wires, add securing for wires within 8" of box, no esc this project
ELE09-01815 Final9/27/20099/28/20099/28/2009 1:21:41 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jenni Keller ok to final, no esc this project
ELE08-02965 DOC - Permit Expired9/28/20099/28/20099/28/2009 9:57:11 AMAPASS
no activity, ok to doc expire, no esc this project
ESC09-00403 General Inspection9/28/20099/28/20099/28/2009 8:55:49 AMAPASS
looked ok
ELE09-01392 Final9/25/20099/28/20099/28/2009 8:51:09 AMAPASS
garage code 31629, thx, TW. Phone #: ###-#### Internet Inspection Request from: Stephen Kren called, ok to final
ELE09-01815 Rough-In Permanent Service9/25/20099/28/20099/25/2009 12:00:00 AMACANC
Phone #: ###-#### Internet Inspection Request from: Jenni Keller