Inspections for the day of: Tuesday, September 28, 2010.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01443 ELE-Aging Inspection9/28/20109/28/20109/29/2010 6:40:59 AM DONE
no activity, suc
ELE10-01432 ELE-Aging Inspection9/28/20109/28/20109/29/2010 6:38:31 AM DONE
suc
ELE09-00317 ELE-Aging Inspection9/28/20109/28/20109/29/2010 6:35:54 AM DONE
no activity, suc
ELE09-00326 ELE-Aging Inspection9/28/20109/28/20109/29/2010 6:34:47 AM DONE
no activity, suc
ELE10-02020 Electrical Rough-In9/28/20109/28/20109/28/2010 3:43:51 PMPPASS
Darren Phone #: ###-#### walls only ok cover
ELE10-02136 Final9/28/20109/28/20109/28/2010 3:31:44 PMPPASS
GARAGE CODE 6675 Phone #: ###-#### >> Inspection requested via web by Dan Rohl ok final
ELE10-02113 Electrical Rough-In9/28/20109/28/20109/28/2010 2:48:54 PMPPASS
Jim Phone #: ###-#### corrections made, ri ok
ELE10-02024 Electrical Rough-In9/28/20109/28/20109/28/2010 1:58:47 PMPFAIL
Contact: Shane Korte Phone #: ###-#### >> Inspection requested via web by Deb Gooden called, wrong number, left correction notice, NEC 210.52(a)(1) no point along floor line shall be over 6' from outlet, 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing member, 334.30 shall staple nm cable within 12" of box or 8" if more than 1, 250.86 shall ground metal boxes
ELE10-02110 Electrical Rough-In9/27/20109/28/20109/28/2010 1:25:46 PMPPASS
conduit before pour foundation//Will ###-#### ok pour foundation
ELE10-02135 Permanent Service9/28/20109/28/20109/28/2010 12:25:03 PMPFAIL
John please call for access Phone #: ###-#### contractor said panel in closet, will fix and recall
GCE10-00087 GCE-Final9/27/20109/28/20109/28/2010 11:22:11 AMAPASS
Scope: FinalContact: Paul @ ###-#### ok final
ELE10-00614 Final9/27/20109/28/20109/28/2010 10:32:45 AMAPASS
Mark or Dale @###-#### Phone #: ###-#### called on outside receptacle, ok final
ELE10-02132 Electrical Rough-In9/27/20109/28/20109/28/2010 9:41:34 AMAPASS
Call Troy ###-#### 30 minutes before. Phone #: ###-#### >> Inspection requested via web by Don Conley ri garage only ok, check at final that garage attached to house
ELE10-02057 Permanent Service9/27/20109/28/20109/28/2010 8:56:05 AMAPASS
electrician Larry M ###-#### Phone #: ###-#### >> Inspection requested via web by Dave Koeppen p/s o/h rec ok
ELE10-01782 Electrical Rough-In9/27/20109/28/20109/28/2010 8:21:45 AMAPASS
cell ###-####
please call to meet Phone #: ###-#### >> Inspection requested via web by Mark M walls only ok cover
ELE10-02057 Final9/27/20109/28/20109/27/2010 5:06:36 PMACANC
electrician Larry M ###-#### Phone #: ###-#### >> Inspection requested via web by Dave Koeppen Inspection cancelled from web by: Dave Koeppen