ELE17-02724
| Electrical Rough-In | 9/28/2017 | 9/28/2017 | 9/28/2017 2:41:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Shower (men's) grid rough in ok cover
|
ELE17-03252
| Final | 9/28/2017 | 9/28/2017 | 9/28/2017 1:28:12 PM | P | FAIL |
|
|
We did the electrical trim only. This house was originally roughed in by another company. Please call Ron at ###-#### for any questions. House should still be open but access code is 5239 key box on west side of garage. If you can reach Ron, Call Jerry at ###-#### Thank you. Phone #: ###-#### Inspection requested via web by Dave Brueggemann 110.3- Equipment shall be wired as per manufacturers instructions. Reverse polarity under stairs, open ground in master closet, patio receptacle not working. 200.6- When using white conductor for ungrounded conductor it shall be identified other than white. Vac circuit. 210.52(C)(3)- Receptacle outlet required at end of peninsula bar. 314.20- Where boxes mounted in tile recessed 1/4" or more extension rings shall be installed. 314.25- All boxes canopies and covers shall completely cover opening. Recessed luminaires shall completely cover box openings. soffits and interior. 334.12- NM cable shall not be installed where subject to physical damage. Garage ladder opening at top. 406.6- Several device covers not installed. Utility, stair, vac opening, disposal. 406.9 and 12- Outdoor receptacle outlets shall be tamper resistant and weather resistant. 422.33- Cord and plug connected jetted tub. Receptacle for tub shall be accessible. Unable to see or test.
|
ELE17-03250
| Temporary Service | 9/27/2017 | 9/28/2017 | 9/28/2017 11:15:45 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon t/s u/g n ok
|
ELE17-03249
| Temporary Service | 9/27/2017 | 9/28/2017 | 9/28/2017 10:54:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kevin blackmon t/s u/g n ok
|
ELE17-02479
| Final | 9/27/2017 | 9/28/2017 | 9/28/2017 10:35:45 AM | A | FAIL |
|
|
Garage Code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk house checked out ok with 110.3- equipment shall not be damaged. Expansion joint broken
|
ELE17-02528
| Final | 9/27/2017 | 9/28/2017 | 9/28/2017 10:17:34 AM | A | CANC |
|
|
Garage Code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Duplicate request
|
ELE17-02528
| Final | 9/27/2017 | 9/28/2017 | 9/28/2017 10:16:24 AM | A | PASS |
|
|
Garage Code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE17-02900
| Electrical Rough-In | 9/27/2017 | 9/28/2017 | 9/28/2017 9:03:14 AM | A | PASS |
|
|
The phone number is ###-#### for our lead installer, Rob Kelley. If you can''t get a hold of him please contact Jesse Simpson at ###-####.
Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson AS per notes from 362
|
ELE17-02900
| Final | 9/28/2017 | 9/28/2017 | 9/28/2017 9:03:05 AM | P | PASS |
|
|
The phone number is ###-#### for our lead installer, Rob Kelley. If you can''t get a hold of him please contact Jesse Simpson at ###-####.
Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson As per notes from 362
|
ELE17-02900
| Electrical Rough-In | 9/27/2017 | 9/28/2017 | 9/28/2017 9:01:58 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jesse Simpson as per notes by 362
|
ELE17-02900
| Final | 9/28/2017 | 9/28/2017 | 9/28/2017 8:41:06 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jesse Simpson As per notes from 362
|