Inspections for the day of: Thursday, September 28, 2017.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-02724 Electrical Rough-In9/28/20179/28/20179/28/2017 2:41:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Shower (men's) grid rough in ok cover
ELE17-03252 Final9/28/20179/28/20179/28/2017 1:28:12 PMPFAIL
We did the electrical trim only. This house was originally roughed in by another company. Please call Ron at ###-#### for any questions. House should still be open but access code is 5239 key box on west side of garage. If you can reach Ron, Call Jerry at ###-#### Thank you. Phone #: ###-#### Inspection requested via web by Dave Brueggemann
110.3- Equipment shall be wired as per manufacturers instructions. Reverse polarity under stairs, open ground in master closet, patio receptacle not working.
200.6- When using white conductor for ungrounded conductor it shall be identified other than white. Vac circuit.
210.52(C)(3)- Receptacle outlet required at end of peninsula bar.
314.20- Where boxes mounted in tile recessed 1/4" or more extension rings shall be installed.
314.25- All boxes canopies and covers shall completely cover opening. Recessed luminaires shall completely cover box openings. soffits and interior.
334.12- NM cable shall not be installed where subject to physical damage. Garage ladder opening at top.
406.6- Several device covers not installed. Utility, stair, vac opening, disposal.
406.9 and 12- Outdoor receptacle outlets shall be tamper resistant and weather resistant.
422.33- Cord and plug connected jetted tub. Receptacle for tub shall be accessible. Unable to see or test.
ELE17-03250 Temporary Service9/27/20179/28/20179/28/2017 11:15:45 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon
t/s u/g n ok
ELE17-03249 Temporary Service9/27/20179/28/20179/28/2017 10:54:24 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon
t/s u/g n ok
ELE17-02479 Final9/27/20179/28/20179/28/2017 10:35:45 AMAFAIL
Garage Code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk
house checked out ok with
110.3- equipment shall not be damaged. Expansion joint broken
ELE17-02528 Final9/27/20179/28/20179/28/2017 10:17:34 AMACANC
Garage Code 1001E
Phone #: ###-#### Inspection requested via web by Alan Lusk Duplicate request
ELE17-02528 Final9/27/20179/28/20179/28/2017 10:16:24 AMAPASS
Garage Code 1001E
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE17-02900 Electrical Rough-In9/27/20179/28/20179/28/2017 9:03:14 AMAPASS
The phone number is ###-#### for our lead installer, Rob Kelley. If you can''t get a hold of him please contact Jesse Simpson at ###-####.

Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson
AS per notes from 362
ELE17-02900 Final9/28/20179/28/20179/28/2017 9:03:05 AMPPASS
The phone number is ###-#### for our lead installer, Rob Kelley. If you can''t get a hold of him please contact Jesse Simpson at ###-####.

Thanks! Phone #: ###-#### Inspection requested via web by Jesse Simpson
As per notes from 362
ELE17-02900 Electrical Rough-In9/27/20179/28/20179/28/2017 9:01:58 AMPPASS
Phone #: ###-#### Inspection requested via web by Jesse Simpson
as per notes by 362
ELE17-02900 Final9/28/20179/28/20179/28/2017 8:41:06 AMPPASS
Phone #: ###-#### Inspection requested via web by Jesse Simpson
As per notes from 362