Inspections for the day of: Wednesday, September 3, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03468 ELE-Aging Inspection9/3/20089/3/20089/5/2008 3:30:20 PM DONE
waiting for contractor to call when done
ELE08-01616 Final9/2/20089/3/20089/3/2008 4:22:08 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jenni Keller ok to final, signed structural card
ELE08-01615 Final9/2/20089/3/20089/3/2008 3:57:14 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jenni Keller ok to final, signed structural card, no esc this project
ESC08-00173 General Inspection9/3/20089/3/20089/3/2008 3:31:13 PMPPART
looked ok
ESC08-00414 General Inspection9/3/20089/3/20089/3/2008 3:22:36 PMPPART
looked ok
ESC08-00607 General Inspection9/3/20089/3/20089/3/2008 3:02:06 PMAPART
looked ok
ESC08-00252 General Inspection9/3/20089/3/20089/3/2008 2:35:24 PMAPART
looked ok
ELE08-02418 Permanent Service9/3/20089/3/20089/3/2008 2:14:46 PMPCANC
Alan Phone #: ###-####, wrong type request, see ri, no esc this project
ELE08-02418 Electrical Rough-In9/3/20089/3/20089/3/2008 2:14:01 PMPPASS
Alan Phone #: ###-#### sup-panel ric ok, no esc this project
ELE08-01603 Permanent Service9/3/20089/3/20089/3/2008 1:13:54 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jim Williams p/s u/g n ok- 1 meter only for house panel
ELE08-01848 Electrical Rough-In9/3/20089/3/20089/3/2008 12:43:58 PMPPASS
Cieling Inspection. Please call Luke at ###-####. Phone #: ###-#### Internet Inspection Request from: Beka Hereau called contractor, ok to cover ceiling in body area only, no esc this project
ELE06-01761 DOC - Permit Expired9/3/20089/3/20089/3/2008 10:14:34 AMADONE
no work going on, tried several times to clear up
ELE08-02402 Permanent Service9/2/20089/3/20089/3/2008 9:59:51 AMAPASS
Please check bonding also. Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton called contractor to add 1 ground rod, talked about panel height, bond metal pipe, bonding at pool ok for fence and mesh, p/s u/g rec ok
ELE08-01572 Rough-In Permanent Service9/2/20089/3/20089/3/2008 9:01:25 AMAPART
Phone #: ###-#### Internet Inspection Request from: Kathy Smith met electrician, ric ok walls and ceiling south side from baths to west only, they still have heaters to install in baths and lights in east utility room
ELE08-01103 Electrical Rough-In9/2/20089/3/20089/3/2008 8:20:39 AMAPART
forest Phone #: ###-#### will look at ceiling after more done, left correction notice,BCC 4.5.54 no violations shall be retained i.e. for example support fixtures, provide fixture disconnects, ground fmc, repair broken covers, no cabling shall be supported on grid or tiles, remove abandoned cable,limit flex length, properly install existing equipment, no esc this project