Inspections for the day of: Thursday, September 3, 2015.
Number of inspections: 4
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-01425 Final9/3/20159/3/20159/3/2015 2:07:30 PMAFAIL
Call David ###-#### for access. Phone #: ###-#### Inspection requested via web by David Nelson Need to add Hot Tub branch circuit to permit fees. NEC 680.34 Requires receptacle to be no less than 6ft. from outside walls of storable Hot Tub.
ELE15-02724 Final8/31/20159/3/20159/3/2015 1:04:39 PMPPASS
Elena Phone #: ###-#### final ok
ELE15-02545 Electrical Rough-In9/2/20159/3/20159/3/2015 10:44:42 AMAFAIL
We are requesting an rough-in inspection for tomorrow 8/3/15 in the early am. Could the inspector please call our PM Todd Hall at ###-#### when he is in route. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate NEC 400.8 still remains, Flexible cord through ceiling grid. BCC 4-05-32 No code voilation shall be retained. NEC 210.8(5) sinks, All 15 and 20 ampere 120 volt receptacles within 6 ft. of the ouside edge of a sink shall have GFCI protection.
ELE15-02624 Electrical Rough-In9/2/20159/3/20159/3/2015 9:23:18 AMAPASS
Chris Phone #: ###-#### Rough-in ok cover hard lid washbay