Inspections for the day of: Tuesday, September 4, 2007.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-02081 Final9/4/20079/4/20079/4/2007 5:09:50 PMPPASS
Scheduled by a contractor via Hello! on 9/4/2007 at 11:17:33 AM. Contact: ###-####. corrections made, ok to final
ELE07-03024 Electrical Rough-In9/4/20079/4/20079/4/2007 4:39:12 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Sean DeLacy walls and hard lids only ok to cover, need address posted
ELE07-02532 Electrical Rough-In9/4/20079/4/20079/4/2007 4:10:29 PMPCANC
Scott; Phone #: ###-#### Internet Inspection Request from: Hattie James see conf
ELE07-02532 Conference9/4/20079/4/20079/4/2007 4:10:08 PMPDONE
Scott; Phone #: ###-#### Internet Inspection Request from: Hattie James owner not ready, too many corrections, reviewed problem areas, he is going to change scope of work and update permit to include service change, talked about prepare concrete encased electrode before pour, 370 said ok to cover u/g for part of driveway where service from house is coming from
ELE06-02660 Final9/4/20079/4/20079/4/2007 3:21:42 PMPPASS
Dave is owner; contractor out of town; Phone #: ###-#### Internet Inspection Request from: Hattie James talked with owner and contr, need to add 2 recpts , id bkr in panel and tighten 1 recpt, ok to final
ELE07-03068 Temporary Service9/4/20079/4/20079/4/2007 3:00:55 PMPFAIL
todd Phone #: ###-#### called, nec 250.53(G) electrode shall be flush with ground, 230.23(B)(4) minimum clearance shall be 18 ft above grade in alley, 230.2 shall supply building with only 1 service, BCC shall provide min 120 and 250 volt recpts with gfci protection
ELE07-02470 Final9/4/20079/4/20079/4/2007 2:36:11 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman ok to final, signed occ card
ELE07-01557 Permanent Service8/28/20079/4/20079/4/2007 1:55:10 PMPPASS
Chris; Phone #: ###-#### Internet Inspection Request from: Hattie James met owner, check sub-panels for ground isolation at ri, p/s u/g rec ok
ELE07-02466 Final8/29/20079/4/20079/4/2007 1:45:50 PMPPASS
James; Phone #: ###-#### Internet Inspection Request from: Hattie James called to label un-labelled breakers, ok to final
ELE07-03070 Rough-In Permanent Service9/4/20079/4/20079/4/2007 1:15:23 PMPFAIL
Mike; Phone #: ###-#### Internet Inspection Request from: Hattie James called, nec 312.5 shall provide abrasion protection for all conductors entering enclosure, 550.32(B) shall meet all criteria for this part of article ( mfgrs instruction to allow service on structure) 250.52(A)(3) concrete encased electrode sahll be provided
ELE07-03067 Permanent Service9/4/20079/4/20079/4/2007 12:47:50 PMPPASS
mitch Phone #: ###-#### called, left message to label breakers not identified, p/s o/h rec ok
ELE07-02982 Rough-In Permanent Service9/4/20079/4/20079/4/2007 12:02:39 PMAPASS
Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson ric ok, p/s u/g n ok
ELE07-01936 Final8/31/20079/4/20079/4/2007 11:06:41 AMAPASS
Ted or Boyd @###-#### are on-site contacts. Thanks Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa ok to final, signed struct card
ELE07-01624 Electrical Rough-In9/4/20079/4/20079/4/2007 10:32:23 AMAPART
Scheduled by a contractor via Hello! on 9/4/2007 at 7:21:11 AM. Contact: ###-####. walls only anop ok to cover
ELE07-03024 Electrical Rough-In9/4/20079/4/20079/4/2007 10:09:23 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Sean DeLacy Inspection cancelled from web by: Sean DeLacy
ELE07-03060 Rough-In Permanent Service8/31/20079/4/20079/4/2007 10:01:51 AMAPASS
###-#### called contr, about recpts, nail plates, ric ok , p/s u/g n ok
ELE07-02684 Final9/4/20079/4/20079/4/2007 9:17:13 AMAPASS
###-#### Internet Inspection Request from: Todd Holbrook ok to final, signed occ card
ELE07-02684 Permanent Service9/4/20079/4/20079/4/2007 9:16:35 AMAPASS
###-#### Internet Inspection Request from: Todd Holbrook p/s u/g rec ok, electrodes ok
ELE07-02963 Electrical Rough-In8/31/20079/4/20079/4/2007 8:49:47 AMAPART
Underground Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton told elect to get set of prints for marking, ok to cover inside perimeter along walls
ELE07-03039 Electrical Rough-In8/31/20079/4/20079/4/2007 8:26:27 AMAPASS
potting & bonding-luis; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt ok to pour equipot plane and potting ok to pour
ELE07-02547 Final8/31/20079/4/20079/4/2007 8:01:51 AMAPART
Contact is Perry. Final inspection for Bakery Dept. only. Phone #: ###-#### Internet Inspection Request from: David Bonner ok to cover bakery clg except cooler area only, signed plan in office
ELE07-02684 Permanent Service8/31/20079/4/20079/4/2007 7:18:48 AMPCANC
###-#### Internet Inspection Request from: Todd Holbrook Inspection cancelled from web by: Todd Holbrook
ELE07-02684 Final8/31/20079/4/20079/4/2007 7:18:44 AMPCANC
###-#### Internet Inspection Request from: Todd Holbrook Inspection cancelled from web by: Todd Holbrook