Inspections for the day of: Wednesday, September 4, 2013.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01975 Final9/4/20139/4/20139/4/2013 2:30:24 PMPPASS
Wants insp this AM?? Told him to call inspector /// homeowner - Dave (alt# ###-####) Phone #: ###-#### ok final
ELE13-01800 Electrical Rough-In9/4/20139/4/20139/4/2013 2:23:56 PMPPASS
she will be there after 3pm // darcelle Phone #: ###-#### ri ok
ELE13-02425 Temporary Service9/4/20139/4/20139/4/2013 2:23:08 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Don Conley t/s u/g n ok
ELE13-02412 Electrical Rough-In9/4/20139/4/20139/4/2013 1:49:26 PMPPASS
As late as possible Phone #: 9398333 >> Inspection requested via mobile web by Dave Seilheimer ri ok, u/g ok cover
ELE13-02410 Electrical Rough-In9/4/20139/4/20139/4/2013 1:31:49 PMPPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI corrections made, ri ok
ELE13-02405 Conference9/3/20139/4/20139/4/2013 12:47:55 PMPDONE
call 1/2 hr before to meet // Kurt Phone #: ###-#### talked about hot tub wiring
ELE13-02405 Final9/4/20139/4/20139/4/2013 12:47:45 PMPPASS
call 1/2 hr before to meet // Kurt Phone #: ###-#### ok final
ELE13-02405 Electrical Rough-In9/4/20139/4/20139/4/2013 12:47:16 PMPPASS
call 1/2 hr before to meet // Kurt Phone #: ###-#### ri ok
ELE13-02399 Permanent Service9/4/20139/4/20139/4/2013 12:17:45 PMPFAIL
Gary Phone #: ###-#### called 414, told home owner that city will void permit and that he must have electrical contractor pull permit for power. Total Electric sent journeyman out to help homeowner and they weren't ready, saw journeyman doing work.
ELE13-01090 Final9/4/20139/4/20139/4/2013 10:31:08 AMAPASS
gate code: *2001 Phone #: ###-#### >> Inspection requested via web by PAT MILLER ok final
ELE13-02181 Final9/3/20139/4/20139/4/2013 10:00:26 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Kevin Koomler ok final
ELE13-02410 Electrical Rough-In9/3/20139/4/20139/4/2013 9:33:32 AMAFAIL
3 unit condo Phone #: ###-#### >> Inspection requested via web by TOM BICANDI called, shall install receptacles per NEC 210, 314 shall flush outside boxes, 334 shall protect attic access cables, 300 shall provide 1 1/4" protection in bored holes, 110 shall close open ko in panel, BCC shall terminate cable in box (#10 in west garage), west panel shall be mounted in wall correctly
ELE13-02421 Rough-In Permanent Service9/4/20139/4/20139/4/2013 8:20:44 AMAPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER ri ok, p/s o/h rec ok, 2 meters required
ELE13-02407 Electrical Rough-In9/3/20139/4/20139/4/2013 7:55:46 AMAPART
Need ok to cover new walls. Lock box code is 2267. it is unoccupied. Phone #: ###-#### >> Inspection requested via web by John Edwards called contractor, left message, new walls only ok cover, need to look at cut-in boxes not wired, shall clean up ceilings