Inspections for the day of: Friday, September 4, 2015.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Page
TitleFIRE INSPECTOR
Phone #208-914-5431
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR15-00544 INSP-Sprinkler Rough-in9/4/20159/4/20159/4/2015 1:58:26 PMPPASS
Underground inspection passed/complete, approved for cover
FIR15-00545 INSP-Sprinkler Rough-in9/4/20159/4/20159/4/2015 1:57:34 PMPPASS
Underground inspection passed/complete, approved for cover
BLD15-02257 FIRE-Final Inspection9/4/20159/4/20159/4/2015 1:33:30 PMPPART
Previously noted items corrected, TCO authorized for 30 days per conversation with Scott Arellano. Fire alarm alarm system to be repaired/altered on a seperste FIR permit by authorized contractor, TCO contigent on fire alarm permit application/review.
BLD15-03088 FIRE-Final Inspection9/3/20159/4/20159/4/2015 12:26:26 PMAPASS
Life fire safety passed/complete
BLD15-03087 FIRE-Final Inspection9/3/20159/4/20159/4/2015 12:26:04 PMAPASS
Life fire safety passed/complete
BLD15-02550 FIRE-Final Inspection9/3/20159/4/20159/4/2015 11:30:50 AMAFAIL
Numerous fire sprinkler escutcheons missing, escutcheons need to be installed. Noticed the ceiling sagging as soon as you walk into tenant space, a fire sprinkler is located in that ceiling tile, the whole head/deflector is above the ceiling, needs to be corrected. Emergency egress lighting in front of tenant space as well as in the storage area of space did not operate, emergency egress lights need to be serviced/replaced.
FIR15-00529 INSP-Final Inspection9/4/20159/4/20159/4/2015 11:08:43 AMPPASS
Final fire sprinkler inspection passed/complete
FIR11-00394 INSP-Final Inspection9/3/20159/4/20159/4/2015 10:54:13 AMAPASS
Final fire alarm inspection passed/complete
BLD15-03002 FIRE-Final Inspection9/3/20159/4/20159/4/2015 10:23:21 AMAPASS
Life fire safety passed/complete
BLD15-01235 FIRE-Final Inspection9/3/20159/4/20159/4/2015 10:11:06 AMAPART
Life fire safety partially complete, interior emergency egress lighting installed but the discharge landings do not have egress lighting, another inspection will be scheduled when exterior egress lighting installed. All other life fire safety items inspected, passed/complete.
FIR15-00472 INSP-Final Inspection9/3/20159/4/20159/4/2015 9:41:24 AMAPASS
Final fire sprinkler inspection passed/complete
FIR15-00407 INSP-Final Inspection9/3/20159/4/20159/4/2015 9:15:40 AMAPASS
Final inspection passed/complete