Inspections for the day of: Thursday, September 5, 2013.
Number of inspections: 22
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC13-00232 General Inspection9/2/20139/2/2013   
ELE12-00194 ELE-Aging Inspection9/5/20139/5/20139/5/2013 4:08:13 PM DONE
Still under construction
GCE13-00146 GCE-Temporary Service9/4/20139/5/20139/5/2013 3:46:09 PMPPASS
Terry ###-#### t/s u/g n ok
ELE13-02372 Temporary Service9/5/20139/5/20139/5/2013 3:07:11 PMPPASS
Garage Code 7517, any questions, please call Clay. Thank You Phone #: ###-#### >> Inspection requested via web by Clay Morgan t/s u/g rec ok
ELE13-02411 Electrical Rough-In9/3/20139/5/20139/5/2013 3:04:21 PMPPASS
customer Teresa Hammer ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Derrick Rough in ok
ELE13-02411 Final9/5/20139/5/20139/5/2013 2:58:46 PMPPASS
customer Teresa Hammer ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Derrick Final ok
ELE13-02282 Final9/5/20139/5/20139/5/2013 2:40:45 PMPPASS
ANY QUESTIONS OR PROBLEMS, CALL PAUL. Phone #: ###-#### >> Inspection requested via web by PAUL PINNEY Final ok
ELE13-02440 Temporary Service9/5/20139/5/20139/5/2013 2:30:42 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g n ok
ELE13-02441 Temporary Service9/5/20139/5/20139/5/2013 2:29:18 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov
110.12- Meter contacts rusted and pitted.
590.6 (A and B)- Ground fault protection shall be provided for personel on 120 volt and 240 volt circuits.
ELE13-02007 Final9/5/20139/5/20139/5/2013 1:23:27 PMPPASS
mike Phone #: ###-#### Final ok
ELE12-01710 Electrical Rough-In9/5/20139/5/20139/5/2013 1:04:14 PMPPASS
Contact: Wes Powell. wall rough in please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Elevator lobby walls floors 9, 10, 12, 13. Rough in ok cover
ELE13-02408 Electrical Rough-In9/4/20139/5/20139/5/2013 12:11:21 PMPPASS
Jeff Pierce on site. Phone #: ###-#### >> Inspection requested via web by Clint Tate Wall rough in ok cover
ELE13-01861 Electrical Rough-In9/4/20139/5/20139/5/2013 10:36:13 AMAPASS
cell 4###-#### Phone #: ###-#### >> Inspection requested via web by Mark M Ceiling rough in ok cover
ELE11-02529 ELE-Aging Inspection9/5/20139/5/20139/5/2013 10:20:06 AM DONE
Still under construction
ELE12-01043 ELE-Aging Inspection9/5/20139/5/20139/5/2013 10:16:37 AM DONE
Still under construction
ELE13-02058 Final9/4/20139/5/20139/5/2013 10:12:54 AMAPASS
This service was looked at for a permanent service inspection. Need final inspection please.
Thanks, Dan Phone #: ###-#### >> Inspection requested via web by Dan Wright Final ok
ELE13-02058 Electrical Rough-In9/4/20139/5/20139/5/2013 10:11:32 AMAPASS
Only relocated existing light fixtures and Fire Alarm devices. Above ceiling work only. Please final is acceptable.
Thank you, Rough in ok
Dan Phone #: ###-#### >> Inspection requested via web by Dan Wright
ELE13-02417 Rough-In Permanent Service9/5/20139/5/20139/5/2013 9:42:02 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov
Garage rough in ok cover p/s o/h n ok
ELE13-02433 Final9/4/20139/5/20139/5/2013 9:25:26 AMAPASS
robert Phone #: ###-#### Final ok
ELE13-02433 Electrical Rough-In9/5/20139/5/20139/5/2013 9:24:54 AMPPASS
robert Phone #: ###-#### Rough in ok
ELE13-02429 Conference9/4/20139/5/20139/5/2013 9:15:03 AMADONE
daniel please call 15 min before going out Phone #: ###-#### Discussed requirements for overhead temp pole
ELE13-02372 Temporary Service9/4/20139/5/20139/5/2013 8:39:42 AMAFAIL
we disconnected all the circuits from the main service and are using it for temporary power. Garage code is 7517, please let me know if there are any issues, Thank You. Clay Morgan Phone #: ###-#### >> Inspection requested via web by Clay Morgan Unable to verify grounding system