ESC13-00548
| General Inspection | 9/5/2013 | 9/5/2013 | 9/10/2013 3:35:07 PM | | PASS |
|
|
site clean,
|
ELE13-02434
| Rough-In Permanent Service | 9/4/2013 | 9/5/2013 | 9/5/2013 4:19:19 PM | P | PASS |
|
|
Chris Phone #: ###-#### rough-in p/s u/g rec ok
|
ELE13-02091
| Electrical Rough-In | 9/5/2013 | 9/5/2013 | 9/5/2013 3:12:16 PM | P | PASS |
|
|
matt - at 3 if possible Phone #: ###-#### rough-in ok cover ceiling grid except at location of above ceiling j-box
|
ELE13-01271
| Permanent Service | 9/5/2013 | 9/5/2013 | 9/5/2013 2:24:16 PM | P | PASS |
|
|
dirk Phone #: ###-#### p/s u/g n ok
|
ELE12-01001
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 1:53:29 PM | P | PASS |
|
|
electric hook up mobile home Phone #: ###-#### >> Inspection requested via web by Thomas wilson final ok
|
ELE12-01002
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 1:49:18 PM | P | PASS |
|
|
electric hook up mobile home Phone #: ###-#### >> Inspection requested via web by Thomas wilson final ok
|
ELE12-01003
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 1:47:37 PM | P | PASS |
|
|
electric hook up mobile home Phone #: ###-#### >> Inspection requested via web by Thomas wilson final ok
|
ELE12-01004
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 1:46:56 PM | P | PASS |
|
|
electric hook up for mobile home Phone #: ###-#### >> Inspection requested via web by Thomas wilson final ok
|
ELE13-00731
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 1:32:22 PM | P | FAIL |
|
|
electric mobile home hook up Phone #: ###-#### >> Inspection requested via web by Thomas wilson NEC 110.26(A)(1) working space for service equipment. 36 inches
|
ELE13-02319
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 12:56:40 PM | P | NR |
|
|
Phone #: ###-#### >> Inspection requested via web by William Andrews Not ready for final at this trime.
|
ELE13-02319
| Rough-In Permanent Service | 9/5/2013 | 9/5/2013 | 9/5/2013 12:53:20 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by William Andrews Sales office rough-in p/s o/h n ok
|
ELE13-02237
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 12:35:04 PM | P | PASS |
|
|
Phone #: 9398333 >> Inspection requested via mobile web by Dave final ok
|
ELE12-01023
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 12:16:51 PM | P | PASS |
|
|
Contact is Mitch Page. Space to be inspected is vacant - formerely Jack''s Flowers. Keys to space are next door at 418 N. Orchard, Basic Computer - see Terry or Sarah. Call Mitch Page before inspecting. Phone #: ###-#### >> Inspection requested via web by Scott Campbell final ok
|
ELE12-01885
| Electrical Rough-In | 9/4/2013 | 9/5/2013 | 9/5/2013 11:45:03 AM | A | FAIL |
|
|
Ceiling in Scion Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton NEC 300.11 (A) Cables and raceways shall not be supported by ceiling grid. NEC 800. The accessible portion of abandoned communications cables shall be removed
|
ELE13-02367
| Electrical Rough-In | 9/5/2013 | 9/5/2013 | 9/5/2013 9:39:28 AM | A | PASS |
|
|
rough in on retrofit in warehouse. We won''t be there till around 8:30 am Phone #: ###-#### >> Inspection requested via web by Tim Dunlop UL listed kits rough-in ok
|
ELE13-01526
| Final | 9/4/2013 | 9/5/2013 | 9/5/2013 9:16:18 AM | A | PASS |
|
|
john Phone #: ###-#### correction done, final ok
|
ELE13-02430
| Electrical Rough-In | 9/4/2013 | 9/5/2013 | 9/5/2013 9:04:19 AM | A | PASS |
|
|
This is a uffer ground inspection. Contact on the job is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover concrete encased electrode
|
ELE12-01067
| ELE-Aging Inspection | 9/5/2013 | 9/5/2013 | 9/5/2013 6:59:11 AM | | DONE |
|
|
under review
|