Inspections for the day of: Thursday, September 6, 2007.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM07-03009 Plumbing Rough-in9/5/20079/6/20079/6/2007 4:34:29 PMPPASS
Sam Phone #: ###-####
PLM07-03011 Groundwork9/5/20079/6/20079/6/2007 3:55:21 PMPPASS
Phone #: ###-#### Internet Inspection Request from: raul castanon
PLM07-03025 Groundwork9/6/20079/6/20079/6/2007 3:55:07 PMPPASS
carlos Phone #: ###-####
PLM07-02586 Plumbing Rough-in9/5/20079/6/20079/6/2007 3:11:09 PMPNR
Call Brad please Phone #: ###-#### Internet Inspection Request from: joe paige
PLM07-03018 Plumbing Rough-in9/6/20079/6/20079/6/2007 2:23:22 PMPPASS
Please call Phil prior to inspection to meet inspector on job site. ###-#### Phone #: ###-#### Internet Inspection Request from: Colleen Brown
PLM07-02434 Groundwork9/6/20079/6/20079/6/2007 2:02:13 PMPPART
This is for the kitchen area. Please call Omar with questions ###-#### Phone #: ###-#### Internet Inspection Request from: Sonja Hankel-g/w in kitchen area on sanitary sewer pass.
PLM07-02981 Water and/or Sewer9/6/20079/6/20079/6/2007 1:38:09 PMPFAIL
air test on sewer test.
PLM07-02470 Water and/or Sewer9/6/20079/6/20079/6/2007 12:37:23 PMAPEND
Phone #: ###-#### Internet Inspection Request from: Brent Lacy-looked at sewer tie in for lacy on east side for 5' of piping that is tied into sewer line that was covered before inspection by someone else,also looked at 6' of sewer & 7' of stormdrain line that tie together on west side and tie into line that was never inspected, will not give approval of inspection till approved plans are issued, if work is covered it is at contractors own risk. under ground piping outside building needs tested.
PLM07-01687 Final9/5/20079/6/20079/6/2007 11:28:35 AMAFAIL
JOB # 2707 Phone #: ###-#### Internet Inspection Request from: Kim Alderson-knock out plug on flr drain in mech room & pipe pan drain to flr drain, kitchen sink vent needs to terminate min of 6" above roof.
PLM07-02210 Plumbing Rough-in9/5/20079/6/20079/6/2007 10:44:49 AMAPASS
Phone #: ###-#### Internet Inspection Request from: David Goitiandia
PLM07-02212 Plumbing Rough-in9/5/20079/6/20079/6/2007 10:44:34 AMAPASS
Phone #: ###-#### Internet Inspection Request from: David Goitiandia
PLM07-02213 Plumbing Rough-in9/5/20079/6/20079/6/2007 10:44:19 AMAPASS
Phone #: ###-#### Internet Inspection Request from: David Goitiandia
PLM07-02981 Water and/or Sewer9/5/20079/6/20079/6/2007 9:27:25 AMAFAIL
Tim; Phone #: ###-#### Internet Inspection Request from: Hattie James-need to test sewer & manhole & camera sewer.
PLM07-02694 Plumbing Rough-in9/5/20079/6/20079/6/2007 8:40:07 AMAFAIL
contact person Jim Cooper Phone #: ###-#### Internet Inspection Request from: Christine Cooper-1 1/2" san tee in overhead is installed backwards & has backgrade where shower vent tie's into lav vent.
PLM07-02586 Plumbing Rough-in9/5/20079/6/20079/5/2007 3:02:47 PMACANC
Call Brad please Phone #: ###-#### Internet Inspection Request from: joe paige Inspection cancelled from web by: joe paige