Inspections for the day of: Tuesday, September 6, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-02666 Final9/1/20169/6/20169/6/2016 2:59:51 PMPCANC
We are doing a service upgrade and the power is getting shut off at 9:00am Call Barry Spencer at ###-#### to see what a good time would be to come out and inspect before Idaho Power turns the power back on. Phone #: ###-#### Inspection requested via web by Thaniel Bishop needed perm service
ELE16-02666 Rough-In Permanent Service9/6/20169/6/20169/6/2016 2:59:21 PMPPASS
We are doing a service upgrade and the power is getting shut off at 9:00am Call Barry Spencer at ###-#### to see what a good time would be to come out and inspect before Idaho Power turns the power back on. Phone #: ###-#### Inspection requested via web by Thaniel Bishop Solar rough in ok. p/s u/g rec ok
ELE16-02822 Final9/6/20169/6/20169/6/2016 2:25:49 PMPFAIL
Joe Phone #: ###-#### 100a breaker is on a 50A max opening. Missing breaker blank in sub panel.
ELE16-02895 Temporary Service9/6/20169/6/20169/6/2016 1:53:23 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov t/s u/g n ok
ELE16-02893 Electrical Rough-In9/6/20169/6/20169/6/2016 1:36:14 PMPPASS
Gate should be open. Call mike###-#### if need access. Garage rough in and perm service Phone #: ###-#### Inspection requested via web by mike brown garage rough in ok
ELE16-02893 Permanent Service9/6/20169/6/20169/6/2016 1:35:07 PMPPASS
Gate should be open. Call mike###-#### if need access. Garage rough in and perm service Phone #: ###-#### Inspection requested via web by mike brown p/s u/g n ok
ELE16-02871 Rough-In Permanent Service9/6/20169/6/20169/6/2016 12:56:55 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in ok p/s u/g n ok
ELE16-02847 Electrical Rough-In9/2/20169/6/20169/6/2016 12:38:23 PMPPASS
Rough-in inspection please. Contact is David Forbes ###-####. He may be on site if you have any questions. If he is not there please give him a call. Thank you and have a super day! Phone #: ###-#### Inspection requested via web by Laura Longshaw Master bath/ bed rough in ok
ELE16-02892 Permanent Service9/6/20169/6/20169/6/2016 12:15:33 PMPPASS
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden p/s o/h rec ok
ELE16-02017 Final9/5/20169/6/20169/6/2016 10:01:56 AMAFAIL
Phone #: ###-#### Inspection requested via web by Jim Williams 210.8 A 1 All receps in bathroom shall be GFCI protected. (Recep next to stool and recep next to Sauna room door)
ELE16-02892 Permanent Service9/6/20169/6/20169/6/2016 9:57:18 AMPFAIL
CONTACT: JASON NOBLE Phone #: ###-#### Inspection requested via web by Deb Gooden
ELE16-02235 Final9/2/20169/6/20169/6/2016 9:26:48 AMAPASS
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
ELE16-02888 Electrical Rough-In9/3/20169/6/20169/6/2016 9:02:46 AMAPASS
Roughing only master bath Phone #: ###-#### Inspection requested via web by Dan Rohl Master bath/ bed wall only ok to cover
ELE16-01977 Electrical Rough-In9/2/20169/6/20169/6/2016 8:46:40 AMAPART
Call Steve when in route if possible. Obtain visitors badge from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy 2 office wall and deviding wall ok to cover Walls only
ELE16-02724 Final9/2/20169/6/20169/2/2016 12:00:00 AMACANC
If Friday afternoon inspection is possible, it would be greatly appreciated. Phone #: ###-#### >> Inspection requested via web by Clint Tate