Inspections for the day of: Tuesday, September 6, 2016.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-03155 Final9/6/20169/6/20169/6/2016 2:49:25 PMPPASS
Contact Jason with any questions Phone #: ###-#### Inspection requested via web by Justin Whitt
PLM16-03155 DOC - Permit Finaled9/6/20169/6/20169/6/2016 2:49:10 PMPPASS
PLM16-01708 Final9/2/20169/6/20169/6/2016 2:31:19 PMPPASS
6424 enter Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
MEC16-02797 Rough-in9/6/20169/6/20169/6/2016 2:29:37 PMPPASS
PLM16-03141 Plumbing Rough-in9/5/20169/6/20169/6/2016 1:55:19 PMPFAIL
Phone #: ###-#### Inspection requested via web by casey lattimer-DWV test fail. Missing nailplate. Need to tent waterlines in attic space. Waterline for ice box needs to be pulled to front so to get at least 3 1/2" of insulation behind. Vent needs to be a minimum of 10' away or 3' above an opening window.
MEC16-02797 Final9/2/20169/6/20169/6/2016 1:10:57 PMPCANC
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
PLM16-03197 Plumbing Rough-in9/2/20169/6/20169/6/2016 1:06:45 PMAPASS
Please call ahead of time so that we can meet you for a walk through. ###-#### Kirk Johns Phone #: ###-#### Inspection requested via web by Kirk Johns
PLM16-01224 Final9/6/20169/6/20169/6/2016 12:35:18 PMPPASS
PLM16-03208 Water and/or Sewer9/6/20169/6/20169/6/2016 10:34:38 AMAPART
Phone #: ###-#### Inspection requested via web by Charles Parks-Ok to cover, pvb needs tested.
PLM16-03159 Final8/31/20169/6/20169/6/2016 10:17:49 AMAFAIL
Please call ###-#### or ###-#### when on way. Call Toven at ###-#### with any questions or concerns
Phone #: ###-#### Inspection requested via web by Ben Davis-Remove tape around b-vent and cannot use a flex connector on a T&P.
PLM16-03157 Final9/2/20169/6/20169/6/2016 10:05:55 AMAFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette-Watersoftner drain requires an airgap and need shut off valve for softner.
PLM16-02812 Final9/2/20169/6/20169/6/2016 8:57:12 AMAPASS
if not open call Ted Devand at ###-#### Phone #: ###-#### Inspection requested via web by david colburn
PLM16-03205 Water and/or Sewer9/5/20169/6/20169/6/2016 8:47:12 AMACANC
Phone #: ###-#### Inspection requested via web by Travis Gingerich-No backflow installed, they are on pressurized irrigation. No permit required.
PLM16-03205 DOC - Permit Finaled9/6/20169/6/20169/6/2016 8:43:48 AMPPASS
PLM16-03190 Water and/or Sewer9/5/20169/6/20169/6/2016 8:15:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM16-03190 DOC - Permit Finaled9/6/20169/6/20169/6/2016 8:15:23 AMPPASS
PLM15-04378 PLM-Aging Inspection9/6/20169/6/20169/6/2016 7:35:10 AM PART
No calls
PLM14-03286 PLM-Aging Inspection9/6/20169/6/20169/6/2016 7:34:39 AM PART
PLM15-03426 PLM-Aging Inspection9/6/20169/6/20169/6/2016 7:34:00 AM PASS
Corrections complete
PLM15-03426 DOC - Permit Finaled9/6/20169/6/20169/6/2016 7:33:35 AMPPASS
PLM15-01246 PLM-Aging Inspection9/6/20169/6/20169/6/2016 7:32:52 AM PASS
PLM15-01246 DOC - Permit Expired9/6/20169/6/20169/6/2016 7:32:43 AMPPASS
MEC15-03324 Mec-Aging Inspection9/6/20169/6/20169/6/2016 6:18:34 AM PART
No calls
MEC16-03699 Pressure Test9/1/20169/6/20169/1/2016 4:14:39 PMACANC
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
MEC16-03699 Rough-in9/1/20169/6/20169/1/2016 4:14:35 PMACANC
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka