Inspections for the day of: Friday, September 6, 2019.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02213 Final9/6/20199/6/20199/6/2019 1:47:29 PMPCANC
first 6 from the N // Kevin Phone #: ###-####...discussed with contractor...rescheduling for Monday AM first thing..9/9/19
ELE19-01973 Final9/6/20199/6/20199/6/2019 1:38:40 PMPFAIL
Phone #: ###-#### Inspection requested via web by Neal Rumsey...
too much to list....correction notice posted on window at job site
ELE19-03347 Rough-In Permanent Service9/6/20199/6/20199/6/2019 12:33:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Ryan Wilson...
rough ok to cover
p/s u/g new ok
ELE19-01529 Final9/5/20199/6/20199/6/2019 11:51:30 AMPCANC
I am working ion Friday but will be home after 2:30 Phone #: ###-#### Inspection requested via web by Ron MacCulloch...
rescheduled to 9/13/19...conflicting schedules inspector and homeowner agreed to reschedule
ELE19-02695 Final9/6/20199/6/20199/6/2019 11:39:51 AMPPASS
garage code 2468, thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn..
ok to final
ELE19-03014 Final9/5/20199/6/20199/6/2019 10:52:57 AMAPASS
Inspector needs to call 30 minutes ahead of the inspection will need to be escorted into the building for security Phone #: ###-#### Inspection requested via web by robert feller..
2 x 20A circuit to xray machine...surface pipe and thru ceiling...both circuits labelled at outlet and in panel
ELE19-03337 Permanent Service9/5/20199/6/20199/6/2019 10:18:23 AMAPASS
inspection for service to energize.cable t v power supply. Alpha cabinet.contact####-####. Phone #: ###-#### Inspection requested via web by andrew dopieralski...p/s u/g new ok
ELE19-03281 Final9/5/20199/6/20199/6/2019 10:04:18 AMACANC
Please call Brodie with any questions @ 08-###-####. Phone #: ###-#### Inspection requested via web by William Salts...no access...contractor will reschedule to next week
ELE19-03260 Electrical Rough-In9/3/20199/6/20199/6/2019 9:48:56 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Lanham...
UL listed equipment verified
requiring clearance in front of panel be made by time of final
will need access to panel in garage at final
ELE19-02945 Electrical Rough-In9/5/20199/6/20199/6/2019 9:29:50 AMACANC
ceiling cover Phone #: ###-#### >> Inspection requested via web by David Feller Inspection cancelled from web by: David Feller
ELE19-03269 Rough-In Permanent Service9/5/20199/6/20199/6/2019 9:26:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn...
rough ok to cover
p/s u/g new ok
ELE18-01889 Electrical Rough-In9/5/20199/6/20199/6/2019 9:01:10 AMAPASS
Kitchen Phone #: ###-#### Inspection requested via web by Debby Pierce...area ok to final and occupy
ELE19-03027 Electrical Rough-In9/5/20199/6/20199/6/2019 8:42:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...
bathroom hard lids x 2 ok to cover
ELE19-03303 Final9/5/20199/6/20199/6/2019 8:28:39 AMAFAIL
Phone #: ###-#### Inspection requested via web by Joseph Yergensen....

Boise city ordinance requires a rough inspection of material before installation or final...material completely installed...material shall be removed to ground level for inspection and UL verification
ELE19-03331 Temporary Service9/5/20199/6/20199/6/2019 7:52:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn....t/s u/g new ok