ELE07-03126
| Conference | 9/7/2007 | 9/7/2007 | 9/10/2007 12:01:46 PM | A | DONE |
|
|
don ###-#### talked with owner yold requirerments and if ? call me
|
ELE07-02493
| Final | 9/7/2007 | 9/7/2007 | 9/7/2007 2:41:56 PM | P | PASS |
|
|
chris Phone #: ###-#### ok
|
ELE07-02495
| Final | 9/7/2007 | 9/7/2007 | 9/7/2007 2:41:39 PM | P | PASS |
|
|
chris Phone #: ###-#### ok
|
ELE07-02494
| Final | 9/7/2007 | 9/7/2007 | 9/7/2007 2:41:25 PM | P | PASS |
|
|
chris Phone #: ###-#### ok
|
ELE07-03122
| Rough-In Permanent Service | 9/7/2007 | 9/7/2007 | 9/7/2007 1:45:15 PM | P | PASS |
|
|
chris Phone #: ###-#### r/i p/s u/g new ok
|
ELE07-03121
| Electrical Rough-In | 9/7/2007 | 9/7/2007 | 9/7/2007 1:19:14 PM | P | PASS |
|
|
chris Phone #: ###-#### r/i ok
|
ELE07-02894
| Rough-In Permanent Service | 9/7/2007 | 9/7/2007 | 9/7/2007 12:47:21 PM | P | PASS |
|
|
dino Phone #: ###-#### ok corr made r/i p/s u/g new ok
|
ELE07-03094
| Electrical Rough-In | 9/7/2007 | 9/7/2007 | 9/7/2007 12:19:32 PM | P | PASS |
|
|
Jesse; Phone #: ###-#### Internet Inspection Request from: Hattie James ok
|
ELE06-02413
| Final | 9/7/2007 | 9/7/2007 | 9/7/2007 12:19:12 PM | P | PASS |
|
|
ok card signed
|
ELE07-02529
| Electrical Rough-In | 9/6/2007 | 9/7/2007 | 9/7/2007 10:23:11 AM | A | PART |
|
|
Cieling Inspection in Office/ Halllway for cover. Please call with any questions. Phone #: ###-#### Internet Inspection Request from: todd hall office and hall ceilings ok
|
ELE05-03536
| Final | 9/6/2007 | 9/7/2007 | 9/7/2007 10:00:35 AM | A | FAIL |
|
|
Please call Jim 30 min. prior@###-####. Phone #: ###-#### Internet Inspection Request from: Heather Packer corr fee due met contr. 210.52(C)(1)&(5) except shall install outlets for countertops and peninsular as codes noted states kit layout was changed after r/i inspection250.32 (B)(1) shall install phases,neut.,m and equip grd from service on fence to house, 250.52(A)(1) grd u/g water at house within 5ft, install 2 grd rods, 225.31,32,36 install service disconnect at either inside or outside upon entry , BCC&110.3(B) secure p/s at fence, and use only 2 pole breakers at milbank COW
|
ELE05-03536
| Permanent Service | 9/7/2007 | 9/7/2007 | 9/7/2007 9:39:37 AM | A | FAIL |
|
|
Please call Jim 30 min. prior@###-####. Phone #: ###-#### Internet Inspection Request from: Heather Packer see note for final inspection
|
ELE06-04230
| Final | 9/6/2007 | 9/7/2007 | 9/7/2007 8:47:30 AM | A | PASS |
|
|
Please call Michelle 30 min. prior@###-#### Phone #: ###-#### Internet Inspection Request from: Heather Packer ok
|
ELE07-02775
| Permanent Service | 9/6/2007 | 9/7/2007 | 9/7/2007 8:36:39 AM | A | FAIL |
|
|
jack Phone #: ###-#### Note: look at garaga also corr called left message needs GEC sized to T250.66 KCmil for 400 amps 250.52(A)(1) need covers for sub panels, need manufactures instruction , can they be use as subpanels or p/s only? neutral jumper removed
|