ESC10-00932
| General Inspection | 9/8/2011 | 9/8/2011 | 9/9/2011 6:27:47 AM | | PASS |
|
|
looked ok
|
ELE10-01669
| ELE-Aging Inspection | 9/8/2011 | 9/8/2011 | 9/9/2011 6:23:39 AM | | DONE |
|
|
still under construction
|
ELE11-01960
| Electrical Rough-In | 9/8/2011 | 9/8/2011 | 9/8/2011 2:59:30 PM | P | PASS |
|
|
TRENT CALL FOR ACCESS Phone #: ###-#### ok cover ceiling
|
ELE08-02423
| Electrical Rough-In | 9/8/2011 | 9/8/2011 | 9/8/2011 2:54:59 PM | P | PASS |
|
|
Greg Phone #: ###-#### ok cover u/g south side east and west
|
ELE11-02057
| Rough-In Permanent Service | 9/7/2011 | 9/8/2011 | 9/8/2011 2:18:13 PM | P | PASS |
|
|
todd Phone #: ###-#### conditional ok, contractor shall call for final, shall add water pipe ground and 2nd ground rod, shall move existing electrical for space about hot tub,shall change range and dryer to 4 wire, shall remove jacketing on gec, shall bring up to code, p/s u/g rec ok
|
ELE11-00882
| Final | 9/8/2011 | 9/8/2011 | 9/8/2011 2:02:33 PM | P | PASS |
|
|
Lynn Phone #: ###-#### ok final
|
ELE11-02072
| Electrical Rough-In | 9/7/2011 | 9/8/2011 | 9/8/2011 1:24:06 PM | P | PASS |
|
|
todd Phone #: ###-#### conditional, shall call for final, shall remove electrical too close to hot tub, add water pipe ground, add 2nd ground rod, remove insulation from ground wire at service, change range and dryer to 4- wire, check load calculation for service, p/s u/g rec ok
|
ELE11-02072
| Final | 9/8/2011 | 9/8/2011 | 9/8/2011 1:24:00 PM | P | PASS |
|
|
ok final
|
ELE11-01865
| Rough-In Permanent Service | 9/7/2011 | 9/8/2011 | 9/8/2011 11:37:38 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ri ok, p/s u/g n ok
|
ELE11-01337
| Final | 9/7/2011 | 9/8/2011 | 9/8/2011 10:03:16 AM | A | PASS |
|
|
We have completed the installation to the Heat Pump. Our Electrician the performed the installation isJose (Can Speak Spanish)@###-####. The Tenant, Andrea Rodrigues (Spanish Speaking) can be reached at ###-####. Thank you. Phone #: ###-#### >> Inspection requested via web by Clint Tate ok final
|
ELE11-02075
| Rough-In Permanent Service | 9/7/2011 | 9/8/2011 | 9/8/2011 9:46:35 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI ri ok, p/s u/g n ok
|
ELE11-02023
| Electrical Rough-In | 9/7/2011 | 9/8/2011 | 9/8/2011 9:04:13 AM | A | PART |
|
|
Partial rough-in. CJ is contact. Walls only w/med grade. Thank you. Phone #: ###-#### >> Inspection requested via web by Chris Chesnut corrections made, ri walls only back part ok
|
ELE11-02069
| Permanent Service | 9/7/2011 | 9/8/2011 | 9/8/2011 8:46:03 AM | A | FAIL |
|
|
Heedo Phone #: ###-#### called, left correction notice, shall provide circuit directory, abrasion protection for conductors, 2 ground rods, 4 wire range and dryer, weather proof receptacle cover, rain-tight fittings, no violations shall be retained, conduit srapping, etc
|
ELE11-01629
| Final | 9/8/2011 | 9/8/2011 | 9/8/2011 7:55:53 AM | A | PASS |
|
|
thanks!!! Phone #: ###-#### >> Inspection requested via web by Darryn Coburn ok final
|