MEC14-03389
| Rough-in | 9/8/2014 | 9/8/2014 | 9/9/2014 9:32:39 AM | P | FAIL |
|
|
-Rough-in is not per manual-j, gas test fail, flue test fail, need to support gas piping, flue for furnace in garage needs to grade uphill, need to seal all tin, need to insulate all tin in unconditioned space with r-6, range exhaust missing.( per less kitchen exhaust is 1200 cfm, told less make-up air is required.)(Less said they are going to install a commercial range, told less cannot install a commercial range in a residential house.)
|
PLM14-02576
| Plumbing Rough-in | 9/7/2014 | 9/8/2014 | 9/8/2014 3:58:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Lee
|
PLM14-02578
| Water and/or Sewer | 9/8/2014 | 9/8/2014 | 9/8/2014 3:52:13 PM | P | NR |
|
|
please call first 941 4484 Inspection requested via web by john brown
|
PLM14-02571
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 3:23:10 PM | A | PASS |
|
|
Phil-would like you to go out as early as possible Phone #: ###-####1
|
MEC14-03310
| Rough-in | 9/3/2014 | 9/8/2014 | 9/8/2014 1:53:33 PM | P | PASS |
|
|
Please call Jason with any questions. Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC14-03310
| Pressure Test | 9/3/2014 | 9/8/2014 | 9/8/2014 1:53:11 PM | P | PASS |
|
|
Please call Jason with any questions. Phone #: ###-#### Inspection requested via web by Lisa Whitney-20 lb gas test pass
|
PLM14-00887
| Water Heater Final | 9/8/2014 | 9/8/2014 | 9/8/2014 1:33:00 PM | P | PASS |
|
|
|
PLM14-02568
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 12:38:23 PM | A | PASS |
|
|
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
|
PLM14-02568
| DOC - Permit Finaled | 9/8/2014 | 9/8/2014 | 9/8/2014 12:30:51 PM | P | PASS |
|
|
|
PLM14-02569
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 12:30:40 PM | A | PASS |
|
|
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
|
PLM14-02569
| DOC - Permit Finaled | 9/8/2014 | 9/8/2014 | 9/8/2014 12:30:27 PM | P | PASS |
|
|
|
PLM14-02570
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 12:30:13 PM | A | FAIL |
|
|
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan-Need to run sewer in approved material (sch 40) when waterlines cross sewer.
|
PLM14-02572
| Water Heater Final | 9/5/2014 | 9/8/2014 | 9/8/2014 11:28:17 AM | A | PASS |
|
|
If you have any questions please contact Mike. Thank you! Phone #: ###-#### Inspection requested via web by Ben Davis
|
PLM14-02535
| Water Heater Final | 9/5/2014 | 9/8/2014 | 9/8/2014 10:39:49 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by Don Beevers- no access, left notice
|
PLM14-02575
| Water Heater Final | 9/7/2014 | 9/8/2014 | 9/8/2014 10:38:54 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by chris thornburg-no access, left notice
|
PLM14-02052
| Final | 9/5/2014 | 9/8/2014 | 9/8/2014 10:11:30 AM | A | PASS |
|
|
Rob Phone #: ###-####
|
PLM14-02041
| Final | 9/5/2014 | 9/8/2014 | 9/8/2014 10:11:13 AM | A | PASS |
|
|
Rob Phone #: ###-####
|
PLM14-02547
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 9:26:14 AM | A | PASS |
|
|
9:00 AM
|
PLM14-02547
| DOC - Permit Finaled | 9/8/2014 | 9/8/2014 | 9/8/2014 9:26:01 AM | P | PASS |
|
|
|
PLM14-01482
| Final | 9/7/2014 | 9/8/2014 | 9/8/2014 8:50:07 AM | A | PASS |
|
|
1905 Phone #: ###-#### Inspection requested via web by Jason Gale
|
PLM14-02567
| Sprinkler (Final) | 9/5/2014 | 9/8/2014 | 9/8/2014 8:49:50 AM | A | PASS |
|
|
Its a backflow inspection. Please if possible have inspection done before 10 a.m. Phone #: ###-#### Inspection requested via web by Arturo Segura
|
PLM14-00887
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 8:49:10 AM | A | CANC |
|
|
Call ahead Katy ###-#### Phone #: ###-#### Inspection requested via web by Don Beevers-changer to pm
|
PLM14-02479
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 8:19:14 AM | A | PASS |
|
|
Dusty''''s phone # above - Inspect 1 ea. 1" water service line in early morning 8-9 am. This will be the 2nd line at this permit address to be inspected Phone #: ###-#### Inspection requested via web by Betty Dibble--2nd waterline pass
|
PLM14-02480
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 8:18:26 AM | A | PASS |
|
|
Dusty''s phone # above - Inspect 1 ea. 1" water service line in early morning 8-9 am. This will be the 2nd line at this permit address to be inspected Phone #: ###-#### Inspection requested via web by Betty Dibble-2nd waterline pass
|
PLM14-01972
| Water and/or Sewer | 9/5/2014 | 9/8/2014 | 9/8/2014 8:07:18 AM | A | PASS |
|
|
Meter tie in and landscape tee. Phone #: ###-#### Inspection requested via web by Brent Lacy-Tie-in and main and drain for future backflow pass.
|
PLM14-02284
| Roof Drains | 9/5/2014 | 9/8/2014 | 9/8/2014 7:45:44 AM | A | PASS |
|
|
Jarrod Phone #: ###-####-South side pass
|
PLM14-02284
| Storm Drains | 9/5/2014 | 9/8/2014 | 9/8/2014 7:07:33 AM | A | CANC |
|
|
First thing
|
PLM14-01052
| PLM-Aging Inspection | 9/8/2014 | 9/8/2014 | 9/8/2014 7:07:08 AM | | CANC |
|
|
No calls
|
PLM14-01050
| PLM-Aging Inspection | 9/8/2014 | 9/8/2014 | 9/8/2014 7:06:40 AM | | PEND |
|
|
No calls
|
PLM14-01054
| PLM-Aging Inspection | 9/8/2014 | 9/8/2014 | 9/8/2014 7:06:06 AM | | PASS |
|
|
|
PLM14-01054
| DOC - Permit Finaled | 9/8/2014 | 9/8/2014 | 9/8/2014 7:05:53 AM | A | PASS |
|
|
|
PLM14-01482
| Water and/or Sewer | 9/7/2014 | 9/8/2014 | 9/7/2014 7:37:19 PM | A | CANC |
|
|
1905 garage Phone #: ###-#### >> Inspection requested via web by Jason Gale Inspection cancelled from web by: Jason Gale
|