Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC14-03389 Rough-in9/8/20149/8/20149/9/2014 9:32:39 AMPFAIL
-Rough-in is not per manual-j, gas test fail, flue test fail, need to support gas piping, flue for furnace in garage needs to grade uphill, need to seal all tin, need to insulate all tin in unconditioned space with r-6, range exhaust missing.( per less kitchen exhaust is 1200 cfm, told less make-up air is required.)(Less said they are going to install a commercial range, told less cannot install a commercial range in a residential house.)
PLM14-02576 Plumbing Rough-in9/7/20149/8/20149/8/2014 3:58:45 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Lee
PLM14-02578 Water and/or Sewer9/8/20149/8/20149/8/2014 3:52:13 PMPNR
please call first 941 4484 Inspection requested via web by john brown
PLM14-02571 Water and/or Sewer9/5/20149/8/20149/8/2014 3:23:10 PMAPASS
Phil-would like you to go out as early as possible Phone #: ###-####1
MEC14-03310 Rough-in9/3/20149/8/20149/8/2014 1:53:33 PMPPASS
Please call Jason with any questions. Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC14-03310 Pressure Test9/3/20149/8/20149/8/2014 1:53:11 PMPPASS
Please call Jason with any questions. Phone #: ###-#### Inspection requested via web by Lisa Whitney-20 lb gas test pass
PLM14-00887 Water Heater Final9/8/20149/8/20149/8/2014 1:33:00 PMPPASS
PLM14-02568 Water and/or Sewer9/5/20149/8/20149/8/2014 12:38:23 PMAPASS
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
PLM14-02568 DOC - Permit Finaled9/8/20149/8/20149/8/2014 12:30:51 PMPPASS
PLM14-02569 Water and/or Sewer9/5/20149/8/20149/8/2014 12:30:40 PMAPASS
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
PLM14-02569 DOC - Permit Finaled9/8/20149/8/20149/8/2014 12:30:27 PMPPASS
PLM14-02570 Water and/or Sewer9/5/20149/8/20149/8/2014 12:30:13 PMAFAIL
sewer ; water Phone #: ###-#### Inspection requested via web by Ashleigh Meligan-Need to run sewer in approved material (sch 40) when waterlines cross sewer.
PLM14-02572 Water Heater Final9/5/20149/8/20149/8/2014 11:28:17 AMAPASS
If you have any questions please contact Mike. Thank you! Phone #: ###-#### Inspection requested via web by Ben Davis
PLM14-02535 Water Heater Final9/5/20149/8/20149/8/2014 10:39:49 AMANH
Phone #: ###-#### Inspection requested via web by Don Beevers- no access, left notice
PLM14-02575 Water Heater Final9/7/20149/8/20149/8/2014 10:38:54 AMANH
Phone #: ###-#### Inspection requested via web by chris thornburg-no access, left notice
PLM14-02052 Final9/5/20149/8/20149/8/2014 10:11:30 AMAPASS
Rob Phone #: ###-####
PLM14-02041 Final9/5/20149/8/20149/8/2014 10:11:13 AMAPASS
Rob Phone #: ###-####
PLM14-02547 Water and/or Sewer9/5/20149/8/20149/8/2014 9:26:14 AMAPASS
9:00 AM
PLM14-02547 DOC - Permit Finaled9/8/20149/8/20149/8/2014 9:26:01 AMPPASS
PLM14-01482 Final9/7/20149/8/20149/8/2014 8:50:07 AMAPASS
1905 Phone #: ###-#### Inspection requested via web by Jason Gale
PLM14-02567 Sprinkler (Final)9/5/20149/8/20149/8/2014 8:49:50 AMAPASS
Its a backflow inspection. Please if possible have inspection done before 10 a.m. Phone #: ###-#### Inspection requested via web by Arturo Segura
PLM14-00887 Water and/or Sewer9/5/20149/8/20149/8/2014 8:49:10 AMACANC
Call ahead Katy ###-#### Phone #: ###-#### Inspection requested via web by Don Beevers-changer to pm
PLM14-02479 Water and/or Sewer9/5/20149/8/20149/8/2014 8:19:14 AMAPASS
Dusty''''s phone # above - Inspect 1 ea. 1" water service line in early morning 8-9 am. This will be the 2nd line at this permit address to be inspected Phone #: ###-#### Inspection requested via web by Betty Dibble--2nd waterline pass
PLM14-02480 Water and/or Sewer9/5/20149/8/20149/8/2014 8:18:26 AMAPASS
Dusty''s phone # above - Inspect 1 ea. 1" water service line in early morning 8-9 am. This will be the 2nd line at this permit address to be inspected Phone #: ###-#### Inspection requested via web by Betty Dibble-2nd waterline pass
PLM14-01972 Water and/or Sewer9/5/20149/8/20149/8/2014 8:07:18 AMAPASS
Meter tie in and landscape tee. Phone #: ###-#### Inspection requested via web by Brent Lacy-Tie-in and main and drain for future backflow pass.
PLM14-02284 Roof Drains9/5/20149/8/20149/8/2014 7:45:44 AMAPASS
Jarrod Phone #: ###-####-South side pass
PLM14-02284 Storm Drains9/5/20149/8/20149/8/2014 7:07:33 AMACANC
First thing
PLM14-01052 PLM-Aging Inspection9/8/20149/8/20149/8/2014 7:07:08 AM CANC
No calls
PLM14-01050 PLM-Aging Inspection9/8/20149/8/20149/8/2014 7:06:40 AM PEND
No calls
PLM14-01054 PLM-Aging Inspection9/8/20149/8/20149/8/2014 7:06:06 AM PASS
PLM14-01054 DOC - Permit Finaled9/8/20149/8/20149/8/2014 7:05:53 AMAPASS
PLM14-01482 Water and/or Sewer9/7/20149/8/20149/7/2014 7:37:19 PMACANC
1905 garage Phone #: ###-#### >> Inspection requested via web by Jason Gale Inspection cancelled from web by: Jason Gale