Inspections for the day of: Tuesday, September 9, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Kinnear
TitleELE-INSPECTOR
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02456 Permanent Service9/9/20089/9/20089/9/2008 4:44:55 PMPPASS
#90749,Q#8231AZP. WIRED A NEW POWER PEDESTAL & PHONE CABINET. JAMES ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell p/s u/g n ok note no esc permit in project
ELE08-02456 Final9/9/20089/9/20089/9/2008 4:44:22 PMPPASS
#90749,Q#8231AZP. WIRED A NEW POWER PEDESTAL & PHONE CABINET. JAMES ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok final
ELE08-02455 Permanent Service9/9/20089/9/20089/9/2008 4:07:29 PMPPASS
#90748,Q#8231AZO. WIRED A NEW POWER PEDESTAL & PHONE CABINET. JAMES ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell p/s u/g n ok note no esc permit in project
ELE08-02455 Final9/9/20089/9/20089/9/2008 4:06:54 PMPPASS
#90748,Q#8231AZO. WIRED A NEW POWER PEDESTAL & PHONE CABINET. JAMES ###-####. Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok final
ELE08-01089 Conference9/9/20089/9/20089/9/2008 3:53:48 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Alan Lusk wrong permit #
ELE08-02490 Permanent Service9/9/20089/9/20089/9/2008 1:49:02 PMPPASS
service change Phone #: ###-#### Internet Inspection Request from: Therrin Robertson p/s o/h reconnect ok note they need to get concrete grounding electrode (either 20ft cu at footing& fondation or rebar in the wall.) they have 10ft metal water connected now. check bonding, sub panel, & grounding electrode at ri or final esc permit has been rec not issued
ESC08-00622 General Inspection9/9/20089/9/20089/9/2008 1:20:33 PMPPASS
sign posted site looks fine
ELE08-02255 Electrical Rough-In9/9/20089/9/20089/9/2008 1:20:03 PMPPASS
Stan- ceiling cover Phone #: ###-#### ok cover ceiling only
ESC08-00552 General Inspection9/9/20089/9/20089/9/2008 11:39:58 AMAPASS
sign posted site looks fine
ESC08-00553 General Inspection9/9/20089/9/20089/9/2008 11:39:22 AMAPASS
sign posted site looks fine
ELE08-02479 Rough-In Permanent Service9/8/20089/9/20089/9/2008 11:38:43 AMANR
ALLEN Phone #: ###-#### job not ready
ELE08-02478 Rough-In Permanent Service9/8/20089/9/20089/9/2008 11:38:15 AMANR
ALLEN Phone #: ###-#### job not ready
ESC08-00622 General Inspection9/9/20089/9/20089/9/2008 8:40:11 AMAPASS
sign posted site looks fine
ELE08-02255 Rough-In Permanent Service9/9/20089/9/20089/9/2008 8:39:31 AMANR
Inspection of ceiling for cover Phone #: ###-#### Internet Inspection Request from: Stan Woodward t/w stan job is not ready he will call it in for this afternoon