ELE09-01637
| Electrical Rough-In | 9/9/2009 | 9/9/2009 | 9/9/2009 3:46:43 PM | P | PASS |
|
|
ryan - please call 1/2 hr prior Phone #: ###-#### ric ok, no esc this project
|
ESC09-00281
| General Inspection | 9/9/2009 | 9/9/2009 | 9/9/2009 3:12:35 PM | P | PASS |
|
|
looked ok
|
ELE09-01472
| Final | 9/9/2009 | 9/9/2009 | 9/9/2009 2:10:32 PM | P | CANC |
|
|
Inspect new panel behind garage port & rough-in in small room in car port (third door from the left). Laundry Circuits. Phone #: ###-#### Internet Inspection Request from: nathan palmer wrong type request, see ri
|
ELE09-01472
| Electrical Rough-In | 9/9/2009 | 9/9/2009 | 9/9/2009 2:10:03 PM | P | PASS |
|
|
Inspect new panel behind garage port & rough-in in small room in car port (third door from the left). Laundry Circuits. Phone #: ###-#### Internet Inspection Request from: nathan palmer ric ok, no esc this project
|
ELE09-01688
| Electrical Rough-In | 9/9/2009 | 9/9/2009 | 9/9/2009 12:53:33 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/9/2009 at 10:02:36 AM. Contact: ###-####. corrections made, ric ok, ok to pour concrete encased electrode
|
ELE09-01688
| Rough-In Permanent Service | 9/9/2009 | 9/9/2009 | 9/9/2009 12:52:14 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 9/9/2009 at 10:02:36 AM. Contact: ###-####. wrong type request, see ri
|
ESC09-00281
| General Inspection | 9/9/2009 | 9/9/2009 | 9/9/2009 10:55:18 AM | A | PASS |
|
|
looked ok
|
ELE09-01134
| Final | 9/9/2009 | 9/9/2009 | 9/9/2009 10:06:12 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/9/2009 at 6:56:54 AM. Contact: ###-####. corrections made, ok to final, can"t add esc response
|
ELE09-01681
| Electrical Rough-In | 9/8/2009 | 9/9/2009 | 9/9/2009 10:03:41 AM | A | FAIL |
|
|
Anayn ###-#### called, left message, left correction notice, NEC 300.14 shall provide 6" free conductor length at boxes, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 110.12(B) electrical equipment and surfaces shall not be contaminated by foreign material, 250.148(C) shall use ground screws in metal boxes, 210.52(A)(2) shall provide receptacles in 2' walls, 334.30 nm cable shall be secured within 12" of panel and boxes, no esc this project
|
ELE09-01688
| Rough-In Permanent Service | 9/8/2009 | 9/9/2009 | 9/9/2009 9:02:04 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 9/8/2009 at 3:13:35 PM. Contact: ###-####. called, left correction notice, NEC 300.14 at least 6" free conductor shall be left at each point where it emerges from raceway for splice, 300.4 shall provide steel plate where bored hole is less than 1 1/4" from edge of framing member, 250.52(A)(3) concrete encased electrode shall have 2" concrete encasement, 230, shall provide service clearance for existing building
|