ELE11-02093
| ELE-Aging Inspection | 9/9/2013 | 9/9/2013 | 9/9/2013 3:38:11 PM | | DONE |
|
|
Electrical contractor trying to make contact with homeowner
|
ELE13-01457
| Rough-In Permanent Service | 9/6/2013 | 9/9/2013 | 9/9/2013 3:13:52 PM | P | PASS |
|
|
Inspection for the new service gear. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in p/s u/g n ok
|
ELE13-01457
| Electrical Rough-In | 9/9/2013 | 9/9/2013 | 9/9/2013 3:03:53 PM | P | PASS |
|
|
Ground inspection for 3 pole lights north end of site. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover
|
ELE13-02294
| Final | 9/9/2013 | 9/9/2013 | 9/9/2013 2:16:58 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes final ok
|
ELE13-02365
| Final | 9/9/2013 | 9/9/2013 | 9/9/2013 2:09:49 PM | P | NR |
|
|
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan Not ready for final at this time. Raceway with unfused conductors between meterbase and panel requires a grounding bushing connection
|
ELE13-02480
| Temporary Service | 9/9/2013 | 9/9/2013 | 9/9/2013 2:03:50 PM | P | NR |
|
|
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan Not ready for final at this time, Raceway with unfused conductors between meter base and panel requires grounding bushing connection
|
ELE13-02365
| Permanent Service | 9/9/2013 | 9/9/2013 | 9/9/2013 1:59:40 PM | P | PASS |
|
|
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan p/s o/h rec ok
|
ELE13-02462
| Final | 9/9/2013 | 9/9/2013 | 9/9/2013 1:18:20 PM | P | FAIL |
|
|
Carol please call 30 min before going out Phone #: ###-#### NEC 210.8(A)(2) All 15 and 20 ampere 120 volt receptacle in a garage of an single family dwelling require GFCI protection
|
ELE13-02453
| Conference | 9/9/2013 | 9/9/2013 | 9/9/2013 1:00:08 PM | P | DONE |
|
|
Discussed with homeowner electrical requirements for wiring upstairs living area
|
ELE00-03086
| Final | 9/5/2013 | 9/9/2013 | 9/9/2013 12:53:48 PM | P | FAIL |
|
|
Call ahead for access - john Phone #: ###-#### NEC 200.10 reverse polarity in kitchen and bedroom receptacles
|
ELE13-02369
| Final | 9/6/2013 | 9/9/2013 | 9/9/2013 12:07:57 PM | P | PASS |
|
|
ON SITE CONTACT GREGG CROW OR LARRY GAMMEL. CALL JIM @ ###-#### WITH QUESTIONS. Phone #: ###-#### >> Inspection requested via web by Amie Rose final ok
|
ELE13-02369
| Electrical Rough-In | 9/9/2013 | 9/9/2013 | 9/9/2013 12:06:15 PM | P | PASS |
|
|
ON SITE CONTACT GREGG CROW OR LARRY GAMMEL. CALL JIM @ ###-#### WITH QUESTIONS. Phone #: ###-#### >> Inspection requested via web by Amie Rose rough-ok
|
ELE13-02183
| Final | 9/9/2013 | 9/9/2013 | 9/9/2013 9:29:37 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes final ok
|
ELE13-02036
| Final | 9/6/2013 | 9/9/2013 | 9/9/2013 8:53:25 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot final ok
|
ELE13-02111
| Final | 9/6/2013 | 9/9/2013 | 9/9/2013 8:33:09 AM | A | PASS |
|
|
Back addition Phone #: ###-#### >> Inspection requested via web by shane vigil final ok
|
ELE13-02294
| Final | 9/9/2013 | 9/9/2013 | 9/9/2013 8:08:32 AM | A | NH |
|
|
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes No access
|
ELE13-01457
| Rough-In Permanent Service | 9/6/2013 | 9/9/2013 | 9/6/2013 4:25:56 PM | A | CANC |
|
|
New service inspection. Contact is Jay April. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Inspection cancelled from web by: Richard Montgomery
|