Inspections for the day of: Monday, September 9, 2013.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02093 ELE-Aging Inspection9/9/20139/9/20139/9/2013 3:38:11 PM DONE
Electrical contractor trying to make contact with homeowner
ELE13-01457 Rough-In Permanent Service9/6/20139/9/20139/9/2013 3:13:52 PMPPASS
Inspection for the new service gear. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in p/s u/g n ok
ELE13-01457 Electrical Rough-In9/9/20139/9/20139/9/2013 3:03:53 PMPPASS
Ground inspection for 3 pole lights north end of site. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery rough-in ok cover
ELE13-02294 Final9/9/20139/9/20139/9/2013 2:16:58 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes final ok
ELE13-02365 Final9/9/20139/9/20139/9/2013 2:09:49 PMPNR
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan Not ready for final at this time. Raceway with unfused conductors between meterbase and panel requires a grounding bushing connection
ELE13-02480 Temporary Service9/9/20139/9/20139/9/2013 2:03:50 PMPNR
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan Not ready for final at this time, Raceway with unfused conductors between meter base and panel requires grounding bushing connection
ELE13-02365 Permanent Service9/9/20139/9/20139/9/2013 1:59:40 PMPPASS
Repaired top 10ft of Mast Phone #: ###-#### >> Inspection requested via web by steve ragan p/s o/h rec ok
ELE13-02462 Final9/9/20139/9/20139/9/2013 1:18:20 PMPFAIL
Carol please call 30 min before going out Phone #: ###-#### NEC 210.8(A)(2) All 15 and 20 ampere 120 volt receptacle in a garage of an single family dwelling require GFCI protection
ELE13-02453 Conference9/9/20139/9/20139/9/2013 1:00:08 PMPDONE
Discussed with homeowner electrical requirements for wiring upstairs living area
ELE00-03086 Final9/5/20139/9/20139/9/2013 12:53:48 PMPFAIL
Call ahead for access - john Phone #: ###-#### NEC 200.10 reverse polarity in kitchen and bedroom receptacles
ELE13-02369 Final9/6/20139/9/20139/9/2013 12:07:57 PMPPASS
ON SITE CONTACT GREGG CROW OR LARRY GAMMEL. CALL JIM @ ###-#### WITH QUESTIONS. Phone #: ###-#### >> Inspection requested via web by Amie Rose final ok
ELE13-02369 Electrical Rough-In9/9/20139/9/20139/9/2013 12:06:15 PMPPASS
ON SITE CONTACT GREGG CROW OR LARRY GAMMEL. CALL JIM @ ###-#### WITH QUESTIONS. Phone #: ###-#### >> Inspection requested via web by Amie Rose rough-ok
ELE13-02183 Final9/9/20139/9/20139/9/2013 9:29:37 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes final ok
ELE13-02036 Final9/6/20139/9/20139/9/2013 8:53:25 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot final ok
ELE13-02111 Final9/6/20139/9/20139/9/2013 8:33:09 AMAPASS
Back addition Phone #: ###-#### >> Inspection requested via web by shane vigil final ok
ELE13-02294 Final9/9/20139/9/20139/9/2013 8:08:32 AMANH
Phone #: ###-#### >> Inspection requested via web by Jesse Fuentes No access
ELE13-01457 Rough-In Permanent Service9/6/20139/9/20139/6/2013 4:25:56 PMACANC
New service inspection. Contact is Jay April. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery Inspection cancelled from web by: Richard Montgomery