ELE12-01594
| ELE-Aging Inspection | 9/9/2014 | 9/9/2014 | 9/9/2014 2:33:19 PM | | DONE |
|
|
Still under construction
|
GCE14-00142
| GCE-Temporary Service | 9/9/2014 | 9/9/2014 | 9/9/2014 2:28:42 PM | P | CANC |
|
|
Andrea ###-#### wrong address contractor will reschedule when corrected
|
ELE14-02496
| Final | 9/9/2014 | 9/9/2014 | 9/9/2014 2:07:24 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
|
ELE14-02496
| Electrical Rough-In | 9/9/2014 | 9/9/2014 | 9/9/2014 1:55:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok
|
ELE14-02490
| Permanent Service | 9/8/2014 | 9/9/2014 | 9/9/2014 1:11:36 PM | P | PASS |
|
|
Please call me when on way ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok
|
ELE14-02501
| Permanent Service | 9/9/2014 | 9/9/2014 | 9/9/2014 12:38:22 PM | P | PASS |
|
|
AJ Phone #: ###-#### 3300 Vista address p/s o/h rec ok
|
ELE14-02461
| Temporary Service | 9/8/2014 | 9/9/2014 | 9/9/2014 12:05:14 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
|
ELE14-00993
| Final | 9/9/2014 | 9/9/2014 | 9/9/2014 12:03:52 PM | P | FAIL |
|
|
Larry Phone #: ###-#### 210.8 Ground-Fault Circuit-Interrupter Protection for Personnel. Ground-fault circuit-interrupter protection for personnel shall be provided as required in 210.8(A) through (D). The ground-fault circuit-interrupter shall be installed in a readily accessible location. Informational Note: See 215.9 for ground-fault circuitinterrupter protection for personnel on feeders. (A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in 210.8(A)(1) through (10) shall have ground-fault circuit interrupter protection for personnel. (6) Kitchens — where the receptacles are installed to serve the countertop surfaces
|
ELE14-02489
| Final | 9/8/2014 | 9/9/2014 | 9/9/2014 10:44:03 AM | A | PASS |
|
|
Robert Phone #: ###-#### AC Final ok
|
ELE14-02489
| Electrical Rough-In | 9/9/2014 | 9/9/2014 | 9/9/2014 10:40:02 AM | P | PASS |
|
|
Robert Phone #: ###-#### AC rough in ok
|
ELE14-02491
| Permanent Service | 9/8/2014 | 9/9/2014 | 9/9/2014 10:22:49 AM | A | FAIL |
|
|
Power has been off for over 12 months. Looked at service and branch circuits. Need inspection for Idaho power to meter. Thanks Phone #: ###-#### Inspection requested via web by Chris Chesnut 250.53(D)(2) Supplemental Electrode Required. A single rod, pipe, or plate electrode shall be supplemented by an additional electrode of a type specified in 250.52(A)(2) through (A)(8). The supplemental electrode shall be permitted to be bonded to one of the following: (1) Rod, pipe, or plate electrode (2) Grounding electrode conductor (3) Grounded service-entrance conductor (4) Nonflexible grounded service raceway (5) Any grounded service enclosure Exception: If a single rod, pipe, or plate grounding electrode 230.27 Means of Attachment. Multiconductor cables used for overhead service conductors shall be attached to buildings or other structures by fittings identified for use with service conductors. Open conductors shall be attached to fittings identified for use with service conductors or to noncombustible, nonabsorbent insulators securely attached to the building or other structure. 230.27 Means of Attachment. Multiconductor cables used for overhead service conductors shall be attached to buildings or other structures by fittings identified for use with service conductors. Open conductors shall be attached to fittings identified for use with service conductors or to noncombustible, nonabsorbent insulators securely attached to the building or other structure.
|
ELE14-02492
| Conference | 9/8/2014 | 9/9/2014 | 9/9/2014 9:43:15 AM | A | PASS |
|
|
Need direction on what will have to be brought up to code. Please call before to meet inspector at job site. Thanks! Phone #: ###-#### Inspection requested via web by Chris Chesnut Discussed minimum required for kitchen remodel. Contractor to provide wiring for 2 small appliance circuits to old fused panel which will tie in as single circuit until service change is done in future. Main concern 3 flexible cords ran through walls in kitchen area to be removed and minimum outlet spacing to be installed.
|
ELE14-02483
| Electrical Rough-In | 9/8/2014 | 9/9/2014 | 9/9/2014 9:12:19 AM | A | PASS |
|
|
Front Sales counter, new outlets installed Phone #: ###-#### Inspection requested via web by Stan Woodward Front counter only rough in ok
|
ELE14-02046
| Final | 9/8/2014 | 9/9/2014 | 9/9/2014 8:57:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|