Inspections for the day of: Tuesday, September 9, 2014.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01594 ELE-Aging Inspection9/9/20149/9/20149/9/2014 2:33:19 PM DONE
Still under construction
GCE14-00142 GCE-Temporary Service9/9/20149/9/20149/9/2014 2:28:42 PMPCANC
Andrea ###-#### wrong address contractor will reschedule when corrected
ELE14-02496 Final9/9/20149/9/20149/9/2014 2:07:24 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
ELE14-02496 Electrical Rough-In9/9/20149/9/20149/9/2014 1:55:17 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok
ELE14-02490 Permanent Service9/8/20149/9/20149/9/2014 1:11:36 PMPPASS
Please call me when on way ###-####. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan p/s o/h rec ok
ELE14-02501 Permanent Service9/9/20149/9/20149/9/2014 12:38:22 PMPPASS
AJ Phone #: ###-#### 3300 Vista address p/s o/h rec ok
ELE14-02461 Temporary Service9/8/20149/9/20149/9/2014 12:05:14 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
ELE14-00993 Final9/9/20149/9/20149/9/2014 12:03:52 PMPFAIL
Larry Phone #: ###-#### 210.8 Ground-Fault Circuit-Interrupter Protection for
Personnel. Ground-fault circuit-interrupter protection for
personnel shall be provided as required in 210.8(A) through
(D). The ground-fault circuit-interrupter shall be installed in
a readily accessible location.
Informational Note: See 215.9 for ground-fault circuitinterrupter
protection for personnel on feeders.
(A) Dwelling Units. All 125-volt, single-phase, 15- and
20-ampere receptacles installed in the locations specified in
210.8(A)(1) through (10) shall have ground-fault circuit interrupter protection for personnel.
(6) Kitchens — where the receptacles are installed to
serve the countertop surfaces
ELE14-02489 Final9/8/20149/9/20149/9/2014 10:44:03 AMAPASS
Robert Phone #: ###-#### AC Final ok
ELE14-02489 Electrical Rough-In9/9/20149/9/20149/9/2014 10:40:02 AMPPASS
Robert Phone #: ###-#### AC rough in ok
ELE14-02491 Permanent Service9/8/20149/9/20149/9/2014 10:22:49 AMAFAIL
Power has been off for over 12 months. Looked at service and branch circuits. Need inspection for Idaho power to meter. Thanks Phone #: ###-#### Inspection requested via web by Chris Chesnut 250.53(D)(2) Supplemental Electrode Required. A single rod, pipe,
or plate electrode shall be supplemented by an additional
electrode of a type specified in 250.52(A)(2) through
(A)(8). The supplemental electrode shall be permitted to be
bonded to one of the following:
(1) Rod, pipe, or plate electrode
(2) Grounding electrode conductor
(3) Grounded service-entrance conductor
(4) Nonflexible grounded service raceway
(5) Any grounded service enclosure
Exception: If a single rod, pipe, or plate grounding electrode
230.27 Means of Attachment. Multiconductor cables used
for overhead service conductors shall be attached to buildings
or other structures by fittings identified for use with
service conductors. Open conductors shall be attached to
fittings identified for use with service conductors or to noncombustible,
nonabsorbent insulators securely attached to
the building or other structure.
230.27 Means of Attachment. Multiconductor cables used
for overhead service conductors shall be attached to buildings
or other structures by fittings identified for use with
service conductors. Open conductors shall be attached to
fittings identified for use with service conductors or to noncombustible,
nonabsorbent insulators securely attached to
the building or other structure.
ELE14-02492 Conference9/8/20149/9/20149/9/2014 9:43:15 AMAPASS
Need direction on what will have to be brought up to code. Please call before to meet inspector at job site. Thanks! Phone #: ###-#### Inspection requested via web by Chris Chesnut Discussed minimum required for kitchen remodel. Contractor to provide wiring for 2 small appliance circuits to old fused panel which will tie in as single circuit until service change is done in future. Main concern 3 flexible cords ran through walls in kitchen area to be removed and minimum outlet spacing to be installed.
ELE14-02483 Electrical Rough-In9/8/20149/9/20149/9/2014 9:12:19 AMAPASS
Front Sales counter, new outlets installed Phone #: ###-#### Inspection requested via web by Stan Woodward Front counter only rough in ok
ELE14-02046 Final9/8/20149/9/20149/9/2014 8:57:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok