ELE19-01480
| Electrical Rough-In | 2/4/2020 | 2/4/2020 | 2/4/2020 2:56:36 PM | P | PASS |
|
|
Call with any questions, thanks! Phone #: ###-#### Inspection requested via web by Rachael Moore... rough-in ok to cover 2 outlets needed added in spare bed and master bed....remove hall outlet off hall bath recep circuit
|
ELE20-00392
| Electrical Rough-In | 2/3/2020 | 2/4/2020 | 2/4/2020 2:02:07 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton...new office area walls and devising wall outlets...ok to cover
|
ELE19-03639
| Electrical Rough-In | 2/4/2020 | 2/4/2020 | 2/4/2020 1:36:39 PM | P | PASS |
|
|
3rd floor rough in Phone #: ###-#### Inspection requested via web by Todd Hall...
3rd floor units rough-in ok to cover
|
ELE20-00377
| Permanent Service | 2/4/2020 | 2/4/2020 | 2/4/2020 12:27:46 PM | P | PASS |
|
|
Should be ready to restore power early afternoon. Phone #: ###-#### Inspection requested via web by Dan Hilke... p/s o/h reconnect ok
|
ELE19-04057
| Electrical Rough-In | 2/4/2020 | 2/4/2020 | 2/4/2020 11:42:24 AM | P | CANC |
|
|
Dirk Phone #: ###-####...required building permit needs pulled before inspection can be done
|
ELE19-03762
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 11:16:57 AM | A | FAIL |
|
|
Rocky Phone #: ###-####...labelling incomplete
|
ELE19-03762
| Electrical Rough-In | 2/4/2020 | 2/4/2020 | 2/4/2020 11:16:33 AM | A | PASS |
|
|
Rocky Phone #: ###-####...listings verified
|
ELE19-04924
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 10:29:30 AM | A | PART |
|
|
Partial final Phase 2 Phone #: ###-#### Inspection requested via web by David Feller... Phase 2 of total project...new cubicle/work stations and breakroom...partial final for area
|
ELE19-01259
| Electrical Rough-In | 2/3/2020 | 2/4/2020 | 2/4/2020 10:05:36 AM | A | PASS |
|
|
Requesting 10:00 am inspection. Install 2 monument signs and three wall signs Phone #: ###-#### Inspection requested via web by Ken Olsen...disconnects and UL labels verified
|
ELE19-04055
| Final | 2/4/2020 | 2/4/2020 | 2/4/2020 9:45:08 AM | A | PASS |
|
|
final for service change...corrections made...ok to final
|
ELE19-04139
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 9:44:34 AM | A | PASS |
|
|
MAIN CONTACT - Levi Henry ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting.... labelling, disconnect, and OCPD ok
|
ELE19-04114
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 9:24:29 AM | A | FAIL |
|
|
Final inspection for Encore Townhomes. The garage door code is 6622. Please let me know if you have any questions. Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings.... 1) all exterior recepticles shall be rated weather resistant...406.9 2) plate for outlet under sink shall be rated to be used with handy box...110.3, 406.6 3) a recepticle shall be within 3ft of edge of each sink in master bathroom...210.52(D)
|
ELE19-04113
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 9:24:02 AM | A | FAIL |
|
|
Final inspection for Encore Townhomes. The garage door code is 6622, Please let me know if you have any question! Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings.... 1) all exterior recepticles shall be rated weather resistant...406.9 2) plate for outlet under sink shall be rated to be used with handy box...110.3, 406.6 3) a recepticle shall be within 3ft of edge of each sink in master bathroom...210.52(D)
|
ELE19-03892
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 9:23:24 AM | A | FAIL |
|
|
Final inspection for Encore Townhomes. The garage door code is 6622, Please let me know if you have any question! Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings.... 1) all exterior recepticles shall be rated weather resistant...406.9 2) plate for outlet under sink shall be rated to be used with handy box...110.3, 406.6 3) a recepticle shall be within 3ft of edge of each sink in master bathroom...210.52(D)
|
ELE19-03706
| Final | 2/3/2020 | 2/4/2020 | 2/4/2020 9:22:41 AM | A | FAIL |
|
|
Final inspection for Encore Townhomes. The garage door code is 6622, Please let me know if you have any question! Thank you, Dan Phone #: ###-#### Inspection requested via web by Dan Jennings..... 1) all exterior recepticles shall be rated weather resistant...406.9 2) plate for outlet under sink shall be rated to be used with handy box...110.3, 406.6 3) a recepticle shall be within 3ft of edge of each sink in master bathroom...210.52(D)
|