Inspections for the day of: Monday, February 3, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05523 Final2/3/20202/3/20202/3/2020 3:22:51 PMPFAIL
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE - No access
MEC19-05397 Final2/3/20202/3/20202/3/2020 3:22:35 PMPPASS
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
MEC19-05522 Final2/3/20202/3/20202/3/2020 3:22:23 PMPPASS
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
MEC19-05353 Final2/3/20202/3/20202/3/2020 3:22:10 PMPPASS
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
MEC19-05071 Rough-in2/3/20202/3/20202/3/2020 2:06:12 PMPFAIL
Rough in roof work. Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist - Plumbing vents need to be 10' away from fresh air intake on MAU
MIS20-00032 MEC-Conference1/31/20202/3/20202/3/2020 10:44:45 AMAFAIL
David Phone #: ###-#### - Penetrations in the corridoor walls need fire/smoke dampers installed
MEC20-00452 Pressure Test1/31/20202/3/20202/3/2020 10:14:06 AMAFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - Missing nail plate on condensate drain for mini split, Missing nail plate on line set for a/c and coil, exhaust fan not connected on 1st floor, register boots on 2nd floor need to secured to joists.
MEC20-00452 Rough-in1/31/20202/3/20202/3/2020 10:12:00 AMAPART
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire - 20lb gas pass, 5lb flue for water heater fail