Inspections for the day of: Tuesday, February 18, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Page
TitleFIRE INSPECTOR
Phone #208-914-5431
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-04490 FIRE-Final Inspection2/18/20202/18/20202/18/2020 2:50:20 PMPCANC
Cancelled per conversation with point of contact due to door swing issue, will be rescheduled for a later date.

Laren Phone #: ###-####
FIR19-00800 INSP-Sprinkler Rough-in2/18/20202/18/20202/18/2020 2:38:59 PMPPASS
Rough to cover inspection for overhead fire sprinkler piping in area of work complete, approved for cover. Notated electrical room on city approved drawing that does not have a ceiling and wall does not go all the up, wall needs to go all the way to the deck or the sprinkler system needs to comply with 8.15.23 of the 2016 NFPA13, will verify during next inspection.

Cole Bierman is the contact for this RTC inspection. Cole is needing a hour notice to get there as he is at another job site. Thank you so much for your help. Phone #: ###-#### Inspection requested via web by Stan Beus
BLD19-04749 FIRE-Final Inspection2/13/20202/18/20202/18/2020 1:41:59 PMAPASS
No fire sprinkler modifications, no fire alarm modifications, fire extinguisher is placed with a current inspection tag. Final life fire safety inspection for area of work complete, signatures provided on permit sign off card.

Nico Phone #: ###-####
BLD20-00420 FIRE-Final Inspection2/18/20202/18/20202/18/2020 1:02:51 PMPFAIL
Repair or replace inoperable exit signs, all exit signs in tenant space did not stay illuminated when A/C power was isolate. Provide annula inspection on fire extinguisher as discussed. Install second piece on the 401 style escutcheon as discussed, 3 are missing.

sue Phone #: ###-####
FIR20-00006 INSP-Sprinkler Rough-in2/14/20202/18/20202/18/2020 10:44:16 AMAPART
Rough to cover inspection for stub in and ductile riser complete, area inspected approved for cover, remaining underground to be installed at a later date.

Contact Tanner Loomis ###-#### 30 min prior to UG RTC insp start please.

Thank YOU Phone #: ###-#### Inspection requested via web by Teri Cruickshank
FIR19-00963 INSP-Final Inspection2/17/20202/18/20202/18/2020 10:19:18 AMAPASS
Final fire alarm inspection for area of work complete.

Contact is Dan. Phone #: ###-#### Inspection requested via web by Morgan Ahten
FIR19-00516 INSP-Conference2/18/20202/18/20202/18/2020 9:57:45 AMPDONE
Fire conference is complete.

Tony Cetani is the contact for this consultation. He is requesting an AM appointment today if possible. Thank you for your help.
Phone #: ###-#### Inspection requested via web by Stan Beus
BLD19-01927 FIRE-Final Inspection2/14/20202/18/20202/18/2020 9:57:19 AMAPART
Partial final inspection for life fire safety is complete for area of work. Fire sprinkler inspection is complete, fire alarm inspection is complete and NFPA72 compliant, waiting on as-builts to be submitted/approved for candella change in corner offices, fire alarm permit can be finaled after fire alarm permit is back in issued status. A formal letter of approveal to the building code official is required from the architect requesting the 2018 chapter 10 IFC exception for stairwell doors to be allowed locked and release on fire alarm activation as well as the combination tumbler look setup on the file room door and secure storage directly south of the file room. Combination looks do not meet IFC requirements for single action operation and will require approval from the building code official. 30 day TCO authorized by Joe Bruce, Fire Section Supervisor.

Phone #: ###-#### Inspection requested via web by Sam Reading