Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00230 Final1/16/20201/21/20201/21/2020 4:13:05 PMPFAIL
Please call prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- need type L clean out tee at bottom of vertical vent
MEC20-00231 Final1/17/20201/21/20201/21/2020 3:40:45 PMPPASS
Homeowner Katie Arrhenius ###-####. This is for trailer #23. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- air handler only ok
MEC20-00236 Pressure Test1/21/20201/21/20201/21/2020 3:28:23 PMPNR
installer john ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- not ready
MEC20-00290 Rough-in1/21/20201/21/20201/21/2020 3:08:36 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- R/I ok
MEC20-00290 Pressure Test1/21/20201/21/20201/21/2020 3:08:11 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
2- 5lb flue tests ok
-20lb gas pressure test ok
-tagged meter location
MEC20-00291 Rough-in1/21/20201/21/20201/21/2020 3:07:41 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
- R/I ok
MEC20-00291 Pressure Test1/21/20201/21/20201/21/2020 3:07:27 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
2-5lb flue tests ok
-20lb gas pressure test ok
-tagged meter location
MEC20-00196 Final1/16/20201/21/20201/21/2020 2:29:13 PMPPASS
Please call Mary on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace only co ok
MEC20-00273 Final1/20/20201/21/20201/21/2020 2:04:38 PMPPASS
Please call Joey on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace ac coil co ok
MEC20-00289 DOC - Permit Finaled1/21/20201/21/20201/21/2020 1:51:09 PMPPASS
final ok
MEC20-00289 Pressure Test1/21/20201/21/20201/21/2020 1:50:48 PMPPASS
Can you call the home owner, Emily at ###-#### about a half hour before heading over? Feel free to call me at ###-####, if there are any issues both with the job, and / issues with getting in touch with Emily.

Nat
###-#### Phone #: ###-#### Inspection requested via web by Nat Golden
- 20lb gas pressure test ok
MEC20-00175 Rough-in1/21/20201/21/20201/21/2020 1:29:51 PMPFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- 5lb flue test
- crawl needs finished
- condensate upstairs needs nail plate
MEC20-00175 Pressure Test1/21/20201/21/20201/21/2020 1:29:10 PMPFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- 5lb flue test fail under 5lb
- 20lb gas pressure test ok
- tagged meter location
MEC20-00287 Rough-in1/21/20201/21/20201/21/2020 1:11:03 PMPFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- 5lb flue test fail
- exhaust fan on 1st floor needs finished
MEC20-00287 Pressure Test1/21/20201/21/20201/21/2020 1:10:29 PMPFAIL
Call Jason with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- 5lb flue test fail under 5lb
- 20lb gas pressure test ok
- tagged meter location
MEC20-00191 DOC - Permit Finaled1/21/20201/21/20201/21/2020 12:19:52 PMPPASS
final ok
MEC20-00191 Rough-in1/17/20201/21/20201/21/2020 12:19:29 PMAPASS
Kenji ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- R/I ok
MEC20-00110 DOC - Permit Finaled1/21/20201/21/20201/21/2020 12:07:52 PMPPASS
final ok
MEC20-00224 Final1/20/20201/21/20201/21/2020 11:58:38 AMAPASS
Please call Ellen prior to arrival if possible.
###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace only co ok
MEC19-03678 Final1/16/20201/21/20201/21/2020 11:43:39 AMAPASS
Homeowner will be there to let you in, thanks Phone #: ###-#### Inspection requested via web by Gary Reeves
- final ok
MEC19-05249 Rough-in1/20/20201/21/20201/21/2020 11:25:01 AMAFAIL
Partial R/I. Please contact Robbie prior to coming to the job ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- supply floor boots need sealed 2nd floor
- range venting need finished
- dryer vent has a few seams that need re sealed
MEC19-05773 Final1/17/20201/21/20201/21/2020 11:20:07 AMACANC
Builder ###-#### - HVAC ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- should have been a R/I
MEC20-00275 Final1/20/20201/21/20201/21/2020 10:58:06 AMAPART
Homeowner (Angie) should be available all day. If there are any issues please give me a call. Thanks. Phone #: ###-#### Inspection requested via web by Josh Johnson
- tankless water heater needs to be on a plumbing permit and up sized gas line needs to be pressure tested. this can all be done on plumbing permit.
- need to see clearances in wall for fireplace termination. fireplace clearances inside ok and no mantel
MEC20-00236 Pressure Test1/16/20201/21/20201/21/2020 10:26:22 AMACANC
INSTALLER JOHN ###-####
LATE A.M. P/T PLEASE Phone #: ###-#### Inspection requested via web by Aaron Alandt
- installer hasn't been to location yet
MEC19-05773 Rough-in1/21/20201/21/20201/21/2020 10:23:55 AMAFAIL
Builder ###-#### - HVAC ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- A/C needs 25 amp fuses installed
- two wall cavities need ducted up to grille
MEC20-00261 Final1/17/20201/21/20201/21/2020 10:08:37 AMACANC
Damon Jordan Phone #: ###-####
- should have been a R/I inspection
MEC20-00261 Rough-in1/21/20201/21/20201/21/2020 10:08:23 AMAFAIL
Damon Jordan Phone #: ###-####
- need paperwork on timble through roof
- stove pipe termination needs to be 2' above roof line
MEC20-00240 Rough-in1/17/20201/21/20201/21/2020 10:07:04 AMAPASS
Call Eric @ ###-#### with any issues. Phone #: ###-#### Inspection requested via web by Angie Maguire
- R/I ok
MEC20-00283 Final1/20/20201/21/20201/21/2020 9:46:07 AMAFAIL
Phone #: ###-#### Inspection requested via web by Pat Jackson
- signle wall connector to stove needs 18" clearances to combustibles
MEC20-00161 Final1/16/20201/21/20201/21/2020 9:06:31 AMAPASS
Customer is requesting an A.M. appointment and a courtesy TEXT prior to arrival. Barbara Decker ###-#### Phone #: ###-#### Inspection requested via web by Shari Wetzler
- furnace only co ok
MEC20-00219 Final1/16/20201/21/20201/21/2020 8:42:24 AMAPASS
PLEASE CALL HOMEOWNER FOR ACCESS Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC19-02868 Mec-Aging Inspection1/21/20201/21/20201/21/2020 8:09:19 AM FAIL
Need to schedule final inspection with homeowner. The only thing that has been seen is a 5lb flue pressure test. Permit has not been active since 9-3-19
MEC19-02838 Mec-Aging Inspection1/21/20201/21/20201/21/2020 8:06:45 AM PASS
Doc Permit Finaled ok
MEC19-02838 DOC - Permit Finaled1/21/20201/21/20201/21/2020 8:06:34 AMAPASS
Doc Permit Finaled ok
MEC19-02850 Mec-Aging Inspection1/21/20201/21/20201/21/2020 8:06:05 AM FAIL
Need to reschedule inspection with home owner. A/C fuses need to be checked then final can be given on permit.