Inspections for the day of: Tuesday, February 11, 2020.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05394 Rough-in2/11/20202/11/20202/11/2020 4:01:56 PMPPASS
Please go around to slider Phone #: ###-#### Inspection requested via web by Shane Taylor
- R/I ok
- check the rest of dryer vent and range vent at final
- water heater closet will need high and low combustion air openings by final
MEC19-05394 Pressure Test2/11/20202/11/20202/11/2020 3:59:50 PMPPASS
Please go around to slider Phone #: ###-#### Inspection requested via web by Shane Taylor
- 20lb gas pressure test ok
- tagged meter location
MEC20-00233 Final2/10/20202/11/20202/11/2020 3:02:11 PMPFAIL
Owner is Joel ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- need to see 1" clearances on new common vent through ceiling and roof
- install insulation sheild on venting in attic
MEC19-05098 Final2/10/20202/11/20202/11/2020 2:40:56 PMPFAIL
Requesting a final inspection. Please contact Robbie prior to arrival. ###-####. Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- need air balance reports/ duct blast sticker needs completed
- line set penetration needs sealed to roof
MEC19-04908 Final2/10/20202/11/20202/11/2020 2:40:26 PMPFAIL
Requesting Final Inspection - Please contact Robbie prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- need air balance reports/ duct blast sticker needs completed
- line set penetration needs sealed to roof
MEC19-05099 Final2/10/20202/11/20202/11/2020 2:39:21 PMPFAIL
Requesting Final Inspection. Please contact Robbie prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- need air balance reports/ duct blast sticker needs completed
- line set penetration needs sealed to roof
MEC19-05248 Rough-in2/10/20202/11/20202/11/2020 2:37:12 PMPPASS
Requesting R/I inspection. Please contact Robbie prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- R/I ok
MEC19-05249 Rough-in2/10/20202/11/20202/11/2020 2:36:56 PMPPASS
Requesting R/I inspection. Please contact Robbie prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- R/I ok
MEC19-05250 Rough-in2/10/20202/11/20202/11/2020 2:36:37 PMPNR
Requesting R/I Inspection. Please contact Robbie prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator
- range venting needs installed
- fresh air ok
MEC20-00575 Final2/10/20202/11/20202/11/2020 1:59:27 PMPNR
Please call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- talked with installer and job is not ready reschedule when work is completed
MEC20-00387 Rough-in2/10/20202/11/20202/11/2020 1:48:53 PMPFAIL
Call when you are on the way so we can ensure someone is there Phone #: ###-#### Inspection requested via web by Dan McFate
- dryer vent needs to be installed in a 2x6 wall as to not smash vent pipe
- line set insulation at indoor unit needs finished
- line set and condensate in crawl need supported
- exhaust fan flex ducting needs rip repaired
- gas line has not been installed yet will need to see pressure test when finished
- plastic coated MC cable for mini split needs UL listed connector installed by final
- adjust permit details to show all items being installed like dryer vent, one exhaust fan, and one A/C for mini split , and gas line which is already in the details
MEC19-04296 Final2/10/20202/11/20202/11/2020 1:16:08 PMPFAIL
AC: 1905 Phone #: ###-#### Inspection requested via web by Gary Reeves
- line set at outdoor unit needs supported
- gas line at furnaces needs supported
- one A/C is sitting on a pallet need to see A/C supported in a finished state
- will need to see the gas line to the pool heater pressure tested once installed. Not sure if this work is being performed by you or others
MEC20-00534 Final2/7/20202/11/20202/11/2020 11:31:47 AMANH
PLEASE CALL HOMEOWNER MIKE WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- called number in notes and no answer
- no access to home left notice on front door
MEC19-04615 Final2/10/20202/11/20202/11/2020 10:45:13 AMAPASS
2468 Phone #: ###-#### Inspection requested via web by Randy Hart
- final ok
MEC20-00579 Pressure Test2/10/20202/11/20202/11/2020 10:11:29 AMAPASS
Gauge is outside Phone #: ###-#### Inspection requested via web by Mary LaFayette
- 20lb gas pressure test ok
- tagged meter location
MEC20-00477 Final2/10/20202/11/20202/11/2020 9:59:30 AMAPASS
Please have inspector call installer Aaron @ ###-#### so that Aaron can meet tech on site for flue test and final inspection Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- 5lb flue pressure test ok
- furnace only ok
MEC19-02327 Rough-in2/10/20202/11/20202/11/2020 9:41:20 AMACANC
Sealant insp. Please call Ted at least 30 min prior to inspection, thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- scheduled wrong site for R/I inspection
- walked NE corner 2nd floor and 1st floor
MEC19-05293 Final2/10/20202/11/20202/11/2020 8:47:52 AMAFAIL
Garage code 5513 Phone #: ###-#### Inspection requested via web by santiago ramirez
- A/C needs locking caps
- arma flex at outdoor unit needs more UV protection
- range venting needs sealed at hood
MEC19-05294 Final2/10/20202/11/20202/11/2020 8:46:55 AMAFAIL
Garage code 5513 Phone #: ###-#### Inspection requested via web by santiago ramirez
- A/C needs locking caps
- arma flex at outdoor unit needs more UV protection
- furnace needs proper air filter installed
- range venting needs sealed at hood
MEC19-05515 Final2/10/20202/11/20202/11/2020 8:45:09 AMAFAIL
Garage code 5513 Phone #: ###-#### Inspection requested via web by santiago ramirez
- A/C needs locking caps
-arma flex at outdoor unit needs more
UV protection
- arma flex at indoor coil needs repaired
- range venting needs sealed at hood
MEC19-05394 Conference2/11/20202/11/20202/11/2020 8:44:43 AMPCANC
back slider is open. please call if you have any questions Phone #: ###-#### >> Inspection requested via web by Shane Taylor Inspection cancelled from web by: Shane Taylor
MIS20-00028 MEC-Conference1/29/20202/11/20202/11/2020 8:06:06 AMAPASS
Owner Bruce Davey ###-####
Check on progress of dryer venting
- Permits have been issued for both locations as of 2-10-20
MIS20-00028 DOC - Permit Finaled2/11/20202/11/20202/11/2020 8:05:30 AMAPASS
Owner Bruce Davey ###-####
Check on progress of dryer venting
- Both locations off of Potter Dr have mechanical permits issued for dryer vents. Advanced pulled permits on 2-10-20
MEC19-03324 Mec-Aging Inspection2/11/20202/11/20202/11/2020 8:02:45 AM FAIL
Permit has not been active since being issued on 7-30-19. Schedule inspection with owner if work is finished. Permit will expire at next mechanical aging inspection if not active.
MEC19-01652 Mec-Aging Inspection2/11/20202/11/20202/11/2020 7:57:56 AM FAIL
Need to schedule a re inspection for corrections that needed to be made. Permit has not been active since failing an inspection on 4-26-19. Permit will expire at next mechanical aging inspection if not active.
MEC19-01508 Mec-Aging Inspection2/11/20202/11/20202/11/2020 7:56:19 AM PASS
WIP
MEC20-00534 Final2/7/20202/11/20202/7/2020 9:09:18 AMACANC
REPLACEMENT OF EXISTING FURNACE ONLY WITH 96% FURNACE Phone #: ###-#### >> Inspection requested via web by Rick Montgomery Inspection cancelled from web by: Rick Montgomery