Inspections for the day of: Thursday, February 27, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00487 BLD-Other2/27/20202/27/20202/27/2020 4:19:34 PMPNR
Hazen Phone #: ###-####//need to insulate for mechanical approval//get mechanical inspection and call for re-inspection//
BLD19-02667 BLD-Wall Bracing2/26/20202/27/20202/27/2020 3:23:22 PMPPASS
Phone #: ###-#### Inspection requested via web by James Jackson
BLD19-04515 BLD-Footing2/26/20202/27/20202/27/2020 2:47:40 PMPPART
Chris Phone #: ###-####//front setbacks tight--will need to remeasure at wall inspection to verify//
BLD20-00104 BLD-Framing/Rough-in2/26/20202/27/20202/27/2020 2:46:58 PMPPASS
Please call 30 minutes in advance Phone #: ###-#### Inspection requested via web by Chase Cheverton//ok to insulate//add ledger screws to ceiling ledger//
BLD19-02407 BLD-Wall Bracing2/26/20202/27/20202/27/2020 1:35:58 PMAPASS
Phone #: ###-#### Inspection requested via web by James Jackson//ok--adding hot dipped galvanized nails while onsite//
BLD19-03992 BLD-Framing/Rough-in2/26/20202/27/20202/27/2020 1:22:19 PMPPASS
Willie Phone #: ###-####//ok to insulate//add stud under two ply beam//add h2.5 at porch cover//need 2 layers 5/8 for 1 hour eave//
BLD19-04576 BLD-Foundation2/26/20202/27/20202/27/2020 11:19:07 AMAPASS
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
BLD19-00646 BLD-Concrete2/26/20202/27/20202/27/2020 10:10:55 AMAPASS
Steve Phone #: ###-####//rebar for CMU wall//ok when top 4 bar installed per drawings//
BLD19-04360 BLD-Framing/Rough-in2/25/20202/27/20202/27/2020 9:51:12 AMANR
Josh Phone #: ###-####//correction notice issued//need to lower egress window//fire block concealed space//air seal//plan mod for changes and beam calcs and address cut beam at end//need mechanical permit//
MIS19-00124 MIS-Aging Inspection2/27/20202/27/20202/27/2020 8:51:01 AM DONE
MIS19-00124 DOC - Permit Finaled2/27/20202/27/20202/27/2020 8:50:52 AMPPASS
permit was issued and finaled//BLD19-01673
BLD18-03781 BLD-Aging Inspection2/27/20202/27/20202/27/2020 8:49:42 AM DONE
Expires: 04/13/20
BLD19-04058 BLD-Aging Inspection2/27/20202/27/20202/27/2020 8:48:59 AM CANC
MIS19-00127 MIS-Aging Inspection2/27/20202/27/20202/27/2020 8:48:12 AM DONE
MIS19-00127 DOC - Permit Finaled2/27/20202/27/20202/27/2020 8:48:03 AMPPASS
see previous entry
BLD20-00325 BLD-Framing/Rough-in2/26/20202/27/20202/27/2020 8:35:11 AMACANC
Jay Walters will be the onsite contact Phone #: ###-#### Inspection requested via web by BRS Permitting//. No work needed to strengthen the existing roof structure per engineer’s roof evaluation.//framing inspection not required//