Inspections for the day of: Thursday, May 21, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS19-00119 MIS-Aging Inspection5/21/20205/21/20205/22/2020 7:15:51 AM PEND
BLD19-00055 BLD-Aging Inspection5/21/20205/21/20205/22/2020 7:14:51 AM CANC
BLD15-01818 BLD-Aging Inspection5/21/20205/21/20205/22/2020 7:13:02 AM PEND
no activity//
BLD19-00541 BLD-Aging Inspection5/21/20205/21/20205/22/2020 7:11:08 AM CANC
BLD20-00337 BLD-Footing5/21/20205/21/20205/21/2020 3:49:45 PMPDEFR
screened // Chase Phone #: ###-####//defer to specials//
BLD19-00535 BLD-Framing/Rough-in5/21/20205/21/20205/21/2020 3:49:10 PMPPART
Prerock areas at exterior walls on 1st -3rd floors Phone #: ###-#### Inspection requested via web by Travis Blackburn//ok when anchor bolts are added at first floor shear walls//
MIS19-00162 BLD-Conference5/21/20205/21/20205/21/2020 3:48:31 PMPDONE
MIS19-00162 DOC - Permit Finaled5/21/20205/21/20205/21/2020 3:48:22 PMPPASS
associated BLD was finaled//
BLD19-00526 BLD-Energy code compliance5/21/20205/21/20205/21/2020 2:04:38 PMPPART
1st floor energy inspection for cover Phone #: ###-#### Inspection requested via web by Travis Blackburn//ok, do not cover area where main fire sprinkler lines are cut through joist, waiting for joist repair/approval before cover//
BLD19-00534 BLD-Wall cover5/21/20205/21/20205/21/2020 2:03:42 PMPPART
3rd and 4th floor drop ceiling inspection for cover along with gyp shear in the entire building Phone #: ###-#### Inspection requested via web by Travis Blackburn//drops ok, third floor pending fire sprinkler approval//shear walls will need to be re-inspected after more screws are added//
BLD20-00003 BLD-Final5/21/20205/21/20205/21/2020 2:02:22 PMPPASS
*screened* Todd Phone #: ###-####//Electrical passed//breakroom and restrooms all existing//phase one of project was inspected for framing etc, phase two was covered with ni inspection, trades passed, appears to meet plans//fire life safety red lines had been completed at final building inspection// appears to meet city approved plans//final complete//
BLD20-01121 BLD-Foundation5/21/20205/21/20205/21/2020 12:31:45 PMPPART
screened // Nate Phone #: ###-####//WIP//rebar installed per plans//
BLD19-03180 BLD-Framing/Rough-in5/21/20205/21/20205/21/2020 11:46:23 AMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//see Joey onsite for corrections list//framing that differs on plans, appears to meet engineers onsite walk through as per the other units//need truss plans on next inspection//also see green marks on plans and in buildings//
BLD19-03181 BLD-Framing/Rough-in5/21/20205/21/20205/21/2020 11:46:02 AMANR
Inspection requested via web by Carl Funk//see Joey onsite for corrections list//framing that differs on plans, appears to meet engineers onsite walk through as per the other units//need truss plans on next inspection//also see green marks on plans and in buildings//
BLD19-03187 BLD-Framing/Rough-in5/21/20205/21/20205/21/2020 11:45:40 AMANR
Inspection requested via web by Carl Funk//see Joey onsite for corrections list//framing that differs on plans, appears to meet engineers onsite walk through as per the other units//need truss plans on next inspection//also see green marks on plans and in buildings//
BLD19-03188 BLD-Framing/Rough-in5/21/20205/21/20205/21/2020 11:43:01 AMANR
Inspection requested via web by Carl Funk//see Joey onsite for corrections list//framing that differs on plans, appears to meet engineers onsite walk through as per the other units//need truss plans on next inspection//also see green marks on plans and in buildings//
BLD20-01191 BLD-Framing/Rough-in5/20/20205/21/20205/21/2020 11:39:20 AMANR
screened // chris Phone #: ###-####//used as conference to discuss structural issues//
BLD20-00875 BLD-Framing/Rough-in5/20/20205/21/20205/21/2020 9:14:07 AMAPASS
gary Phone #: ###-####//ok to insulate only//ok to cover interior walls when air seal has been completed//