Permit Information
Permit NumberBLD00-00235
StatusFinaled
Name M E PROPERTIES INC
Site Address 1501 N 13TH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
To remodel an existing 1,267 sq.ft. space, formerly a coffee / sandwich shop, for use as a restaurant. Work to include remodel of the food prep / kitchen area for installation of a Type I grease hood & exhaust duct W/ 1-hour rated shaft assembly of duct. To modify one of the exisitng restrooms for accessibility compliance and accessible route thereto; to install a new entry door on the 13th Street side W/I existing glazing system; install one new 6'-0" x 3'-0" window as shown and header per engineering / plans. To upgrade electrical & plumbing, to include grease trap, to service new kitchen equipment. All per approved plans notes and attachments. (P.C.#078-00)/drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection6/20/20006/21/20006/21/2000APASS
DetailsRick Jackson
Yes he has an assembly permit through the clerks
BLD-Final6/20/20006/20/20006/20/2000PPASS
Details
Added by Inspector: 338 On 6/20/00 made ok for occ req card signoff by office
Permanent Occupancy 6/20/20006/20/2000 DONE
Details
Permanent Occupancy 6/20/20006/20/2000 DONE
Details
BLD-Final3/22/20003/23/20003/23/2000APART
DetailsRuss Owen
Steve Youngerman ###-#### Need fire life safety 3/23/00 1:37:14 PM
BLD-Final3/23/20003/23/20003/23/2000PPART
Details
###-#### RICK WILL BE THERE AT 1:30 temp made ok 03/24/2000 8:44:55 AM
FIRE-Final Inspection3/23/20003/23/20003/23/2000PPART
DetailsRick Jackson
HE SAID YOU COULD DO THIS AT 1:30 // ###-#### Need assembly permit 3/24/00 1:08:48 PM
BLD-Conference3/21/20003/21/20003/21/2000ACANC
DetailsRick Jackson
Ready at PM
FIRE-Conference3/21/20003/21/20003/21/2000 PART
DetailsRick Jackson
Exiting; extinguishing system requirements 3/22/00 9:21:37 AM
BLD-Framing/Rough-in3/14/20003/14/20003/14/2000PPART
Details
fireshaft bob ###-#### framing for the rsted shaft made ok 3/14/00 4:56:29 PM
BLD-Framing/Rough-in3/8/20003/9/20003/9/2000APART
Details
Bob ###-#### met with contr. discussed the assy to be used for the grease shaft and the termination of same top and bottom per 337 top must terminate at the elevation above the highest roof. 3/9/00 10:19:34 AM
BLD-Framing/Rough-in3/6/20003/7/20003/7/2000APART
DetailsRuss Owen
###-#### Suggested meeting with mechanical inspector for hood exhaust. 3/7/00 1:43:26 PM
BLD-Framing/Rough-in2/17/20002/18/20002/18/2000AFAIL
DetailsJim Storey
bob ###-#### fr No access to bldg. unable to see if beam's were reeingieered for size. 2/22/00 10:15:09 AM