Permit Number | BLD00-00687 |
Status | Finaled |
Name |
STREET ALONZO & SANDRA AND
|
Site Address |
1655 W FAIRVIEW AVE
|
Project Name | |
Customer Number | |
ePlanReview | No |
Description |
To remodel existing 513 s.f. tenant space, Suite 208, located on second floor by constructing 16 ft of non-bearing wall to create a 45 sq. ft. storage room accessed by an existing 20 minute door/frame assembly. To install a new 20 minute smoke & draft door assembly as a new access / egress door for the space per the 1997 UBC for labeling requirements. To remove & relocate interior wall to create larger private office W/I space and install new interior divider wall to break up existing open office area. To remove recessed light fixture's & repair ceiling membrane openings with 1-hour fire-resistive materials to maintain 1-hour roof ceiling assembly; to install new light fixture's with penetrations properly fire-stopped. Per contractor, existing mechanical difussers are fire dampered, no new diffussers being added. All per approved plans, to include plan review notes & attachments to plans. PC#00-193/drs
|