BLD-Final | 10/16/2001 | 10/16/2001 | 10/16/2001 | P | PASS |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 10/16/2001 at 08:03:45. Contact: ###-####.
|
BLD-Final | 10/9/2001 | 10/9/2001 | 10/9/2001 | P | FAIL |
Carl Dependahl
|
|
|
###-####, c/n smoke dets, handrail & landing at deck 10/9/2001 5:56:47 PM
|
BLD-Final | 10/5/2001 | 10/5/2001 | 10/5/2001 | P | NR |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 10/05/2001 at 10:23:55. Contact: ###-####. need fp final...no further insp performed 10/5/2001 3:01:44 PM
|
BLD-Framing/Rough-in | 6/14/2001 | 6/14/2001 | 6/14/2001 | P | PART |
Carl Dependahl
|
|
|
michelle ###-#### rock ok 6/14/2001 11:14:32 AM
|
BLD-Energy code compliance | 6/8/2001 | 6/11/2001 | 6/11/2001 | A | PASS |
Dave Hannah
|
|
|
michelle ###-#### installation
|
BLD-Energy code compliance | 6/8/2001 | 6/8/2001 | 6/8/2001 | P | PART |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 6/8/2001 4:21:08 PM ok to cover
|
BLD-Framing/Rough-in | 6/4/2001 | 6/5/2001 | 6/5/2001 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 06/04/2001 at 17:02:57. Contact: ###-####. beam calc. ok fire blk at basement in progess to be checked at insulation. hangers nailling at header to up stairs and hangers required at header down stairs. 6/5/2001 11:45:20 AM
|
BLD-Footing | 4/17/2001 | 4/17/2001 | 4/17/2001 | P | FAIL |
Carl Dependahl
|
|
|
###-####; c/n need plans submitted for porch ftgs, justify beams, complete fireblox, etc. 4/17/2001 4:47:14 PM
|
BLD-Framing/Rough-in | 11/6/2000 | 11/6/2000 | 11/6/2000 | P | PART |
Tom Arcoraci
|
|
|
shear nailing\\###-#### 11/6/2000 3:42:37 PM ok to side 11/6/2000 3:43:48 PM
|
BLD-Foundation | 9/5/2000 | 9/6/2000 | 9/6/2000 | A | PART |
Tony Young
|
|
|
###-####
|
BLD-Footing | 9/1/2000 | 9/5/2000 | 9/5/2000 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 09/01/2000 at 15:59:13. Contact: ###-####.
|
BLD-Footing | 7/17/2000 | 7/18/2000 | 7/18/2000 | P | PASS |
Tony Young
|
|
|
MICHELLE-- ###-#### FT Footing of stem wall ok 7/19/00 10:01:56 AM
|
BLD-Footing | 7/14/2000 | 7/17/2000 | 7/17/2000 | A | NR |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 07/14/2000 at 16:46:50. Contact: ###-####.
|
BLD-Conference | 6/29/2000 | 6/30/2000 | 6/30/2000 | P | CONF |
Tony Young
|
|
|
###-#### under floor clearance ok under O/D part of house 7/3/00 8:25:35 AM
|
BLD-Foundation | 5/25/2000 | 5/25/2000 | 5/25/2000 | P | PASS |
|
|
|
###-#### ok to pour 5/26/00 7:02:18 AM
|
BLD-Footing | 5/18/2000 | 5/18/2000 | 5/18/2000 | P | PART |
|
|
|
###-#### ok to pour footings front and rear 5/18/00 4:41:05 PM
|