Permit Information
Permit NumberBLD00-02813
StatusFinaled
Name LINGER LONGER LODGE APARTMENTS
Site Address 869 N MAPLE GROVE RD
Project NameLINGER LONGER LODGE AP
Customer Number 
ePlanReviewNo
Description
BUILDING # 7 - TYPE A * 7 units (SECTION 1 OF 2) A TWO HOUR AREA SEPARATION WALL WILL DIVIDE THIS 16 UNIT APARTMENT BUILDING INTO TWO. TO CONSTRUCT A NEW 11,146 SQ.FT. THREE STORY APARTMENT BUILDING. THE FIRST FLOOR CONTAINS 9 GARAGES, ONE, TWO BEDROOM UNIT. THE SECOND FLOOR IS 4,257 SQ.FT AND CONTAINS TWO, TWO BEDROOM UNITS AND TWO, ONE BEDROOM UNITS. THE THIRD FLOOR IS 2,725 SQ.FT AND CONTAINS TWO, TWO BEDROOM UNITS. ALL CONSTRUCTION PER THE APPROVED PLANS. NOTE: THIS BUILDING IS FIRE SPRINKLERED WITH A NFPA 13-R RESIDENTIAL SPRINKLER SYSTEM AND CAN NOT BE USED FOR ANY CODE REDUCTIONS. REFER TO BLD 01-1287 FOR OTHER SIDE OF THE AREA SEPARATION WALL. MJP DRH 99-126 CUP 00-00061 PC#765-00 ** PLAN MODIFICATION 5/15/01
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection12/11/200212/11/200212/11/2002 CANC
DetailsRuss Owen
Permanent Occupancy 11/19/200111/19/2001 DONE
Details
BLD-Final10/16/200110/16/200110/16/2001PPART
DetailsRuss Owen
###-####. ok temp oc. 10/16/2001 4:50:08 PM
BLD-Final10/3/200110/3/200110/3/2001PPASS
DetailsJoe Tawney
Added by Inspector: 406 On 10/3/2001 3:21:41 PM Fire alarm & fire sprk OK. OK for perm. occ.
BLD-Framing/Rough-in8/22/20018/22/20018/22/2001PFAIL
DetailsRuss Owen
###-#### johnc/n posted in job trailer. 8/22/2001 3:54:39 PM
BLD-Framing/Rough-in8/14/20018/14/20018/14/2001PPART
DetailsRuss Owen
hn ###-#### bldg #7. 2 units need fire caulking at some areas. 8/14/2001 4:25:51 PM
BLD-Energy code compliance8/1/20018/2/20018/2/2001APART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 08/01/2001 at 11:34:10. Contact: ###-####.. ok except some of the 2 hr area sep wall will recall. 8/2/2001 11:28:59 AM
BLD-Energy code compliance7/26/20017/26/20017/26/2001PFAIL
DetailsRuss Owen
John ###-####
BLD-Framing/Rough-in7/26/20017/26/20017/26/2001PFAIL
DetailsRuss Owen
John ###-####
BLD-Framing/Rough-in7/20/20017/20/20017/20/2001PFAIL
DetailsRuss Owen
###-####c/n penetrations. 7/20/2001 3:33:45 PM
BLD-Framing/Rough-in7/6/20017/6/20017/6/2001PPASS
DetailsRuss Owen
###-####ok to side. 7/6/2001 3:50:52 PM
BLD-Framing/Rough-in6/27/20016/28/20016/28/2001APART
DetailsRuss Owen
###-#### ok to side 6/28/2001 11:26:20 AM
FIRE-Alarm Testing5/18/20015/21/20015/21/2001APASS
DetailsJoe Tawney
###-#### Conf with Lea Elect reg exit signs. Adv not req by code 5/22/2001 10:49:09 AM
BLD-Concrete4/13/20014/13/20014/13/2001PPART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 04/13/2001 at 11:17:46. Contact: ###-####.garage, int 4/13/2001 4:17:27 PM
BLD-Foundation3/27/20013/28/20013/28/2001APART
DetailsDave Hannah
###-####
BLD-Footing3/19/20013/20/20013/20/2001APART
DetailsRuss Owen
###-####ext footings . 3/20/2001 11:39:14 AM