BLD-Final | 3/29/2001 | 3/30/2001 | 3/30/2001 | A | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 03/29/2001 at 14:55:15. Contact: ###-####. C. of C. #21416 issued. 3/30/2001 8:29:58 AM
|
BLD-Final | 3/28/2001 | 3/29/2001 | 3/29/2001 | A | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 03/28/2001 at 13:43:32. Contact: ###-####.C/N issued-elec. final needed, debris removed from crawl, garage door needs adjustment to self-close. 3/29/2001 8:40:08 AM
|
BLD-Energy code compliance | 2/16/2001 | 2/16/2001 | 2/16/2001 | P | PASS |
Russ Owen
|
|
|
###-####
|
BLD-Framing/Rough-in | 2/15/2001 | 2/15/2001 | 2/15/2001 | P | PASS |
Steven Webb
|
|
|
reinspection Kent ###-####
|
BLD-Framing/Rough-in | 2/14/2001 | 2/14/2001 | 2/14/2001 | P | FAIL |
Steven Webb
|
|
|
Kent ###-####: c/n posted--Address needed on site; hd's on porch column needs nailing; fireblocks needed at stairs and in great room, stairs don't comply with code, header is needed in dinning room, headers in b.fast nook and m.bed not per plans. 2/14/2001 1:38:21 PM
|
BLD-Other | 2/5/2001 | 2/6/2001 | 2/6/2001 | A | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 02/05/2001 at 18:06:22. Contact: ###-####. Shear ok 2/6/2001 9:00:09 AM
|
BLD-Framing/Rough-in | 2/5/2001 | 2/5/2001 | 2/5/2001 | P | PART |
Steven Webb
|
|
|
###-#### ok to side except garage front, nailing with 8d at 2" and 12" oc per plans. 2/5/2001 1:34:38 PM
|
BLD-Foundation | 12/11/2000 | 12/12/2000 | 12/12/2000 | A | PART |
Carl Dependahl
|
|
|
FOUND WALL- CHRIS -###-####
|
BLD-Footing | 12/11/2000 | 12/11/2000 | 12/11/2000 | P | PASS |
Tom Arcoraci
|
|
|
###-####
|