BLD-Final | 5/3/2001 | 5/4/2001 | 5/4/2001 | A | PASS |
Steven Webb
|
|
|
matt ###-#### fn occ C. of C.#21443 issued. 5/4/2001 12:09:28 PM
|
BLD-Final | 5/2/2001 | 5/2/2001 | 5/2/2001 | P | FAIL |
Russ Owen
|
|
|
matt ###-####c/n handrail in garage req. 12/2/2001 2:57:49 PM
|
BLD-Energy code compliance | 2/27/2001 | 3/1/2001 | 3/1/2001 | P | PASS |
Steven Webb
|
|
|
|
BLD-Framing/Rough-in | 2/27/2001 | 2/28/2001 | 2/28/2001 | A | PASS |
Steven Webb
|
|
|
###-####
|
BLD-Framing/Rough-in | 2/26/2001 | 2/27/2001 | 2/27/2001 | A | FAIL |
Steven Webb
|
|
|
Matt ###-####C/N posted--solid bearing under garage truss CO1G; air seal package needed, rotation block at porch and patio bottom trusses, solid connection on 4X4 post at front porch. 2/27/2001 10:28:38 AM
|
BLD-Other | 2/19/2001 | 2/20/2001 | 2/20/2001 | A | PASS |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 02/19/2001 at 10:30:49. Contact: ###-####. exterior sheer panels ok for cover. 2/21/2001 9:07:56 AM
|
BLD-Foundation | 1/30/2001 | 1/30/2001 | 1/30/2001 | P | PART |
Steven Webb
|
|
|
###-#### Footing is less than plans called out, requested engineering, wall forms appears to be ok, hd not installed at time of inspection. 1/30/2001 2:37:08 PM
|
BLD-Footing | 1/26/2001 | 1/29/2001 | 1/29/2001 | P | PART |
Steven Webb
|
|
|
Todd ###-####-setback, soil ok, rebar not installed at time of inspection, reviewed plans. 1/29/2001 2:27:13 PM
|