BLD-Final | 2/5/2002 | 2/5/2002 | 2/5/2002 | A | PASS |
Carl Dependahl
|
|
|
All other trades signed off on card. 325...c/ n ok 2/5/2002 11:43:21 AM
|
Permanent Occupancy | | 2/5/2002 | 2/5/2002 | | DONE |
|
|
|
|
BLD-Final | 12/7/2001 | 12/7/2001 | 12/7/2001 | P | FAIL |
Carl Dependahl
|
|
|
###-#### keep c/n re stage handrails, rear deck guards...main landings ok. 12/7/2001 4:36:47 PM
|
BLD-Aging Inspection | 11/7/2001 | 11/7/2001 | 11/7/2001 | | NR |
Carl Dependahl
|
|
|
wip, keep c/n 11/7/2001 4:29:21 PM
|
BLD-Conference | 11/7/2001 | 11/7/2001 | 11/7/2001 | P | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 11/7/2001 4:36:31 PM w/ Icon re c/n...bring landings to level w/ floor
|
BLD-Final | 9/6/2001 | 9/7/2001 | 9/7/2001 | A | FAIL |
Carl Dependahl
|
|
|
###-#### c/n, deck guard rails, landings, complete decorative fa 9/7/2001 12:04:09 PM cade & handrails at stage steps 9/7/2001 12:05:09 PM
|
BLD-Final | 9/6/2001 | 9/6/2001 | 9/6/2001 | P | FAIL |
Jim Storey
|
|
|
fn - harry- ###-#### basement fire stopping/firedamper labling/ flush bolt at bottom of inactive leaf/ adjust door closer to latch. 9/6/2001 5:19:34 PM
|
FIRE-Final Inspection | 8/31/2001 | 8/31/2001 | 8/31/2001 | P | PASS |
Rick Jackson
|
|
|
###-#### HARRY
|
FIRE-Final Inspection | 8/30/2001 | 8/30/2001 | 8/30/2001 | P | FAIL |
Rick Jackson
|
|
|
Harry ###-#### exsisting exterior stairs have over 1inch from sill to landing; panic hardware not installed; occupant load sign; penetrations in 1 hr lid in basement 8/30/2001 1:11:29 PM
|
BLD-Conference | 8/27/2001 | 8/28/2001 | 8/28/2001 | A | PASS |
Carl Dependahl
|
|
|
for conf-- perry-###-####; w/ contractor re final req's 8/28/2001 10:57:26 AM
|
BLD-Conference | 8/23/2001 | 8/23/2001 | 8/23/2001 | P | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 8/23/2001 4:09:15 PM advised contractor to obtain c/o prior to occupancy.
|
BLD-Framing/Rough-in | 8/8/2001 | 8/8/2001 | 8/8/2001 | P | PART |
Carl Dependahl
|
|
|
perry ###-#### fr insp , cover or remove paneling <1/4" at stairs. headroom issue ok as is existing condition 8/8/2001 1:47:51 PM
|
BLD-Conference | 7/26/2001 | 7/27/2001 | 7/27/2001 | A | CANC |
Tom Arcoraci
|
|
|
Harry ###-#### wil call for 7-30-01 7/26/2001 10:08:16 PM
|
BLD-Conference | 5/30/2001 | 5/30/2001 | 5/30/2001 | P | PART |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 5/30/2001 2:53:40 PM need smoke-flame spread info for scrim at lid
|
BLD-Framing/Rough-in | 5/22/2001 | 5/22/2001 | 5/22/2001 | P | PART |
Jim Storey
|
|
|
Perry ###-#### mech to do rough in after will need access talked to lightfoot ok/ main floor ok for cover / back stair head height check with slane. 5/22/2001 4:12:31 PM
|
BLD-Conference | 5/15/2001 | 5/15/2001 | 5/15/2001 | P | PART |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 5/15/2001 3:07:55 PM w/ bldr, ok to firestop flue at floorline
|
BLD-Conference | 4/30/2001 | 4/30/2001 | 4/30/2001 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 4/30/2001 11:56:29 AM w/ bldr re glazing, handrail issues.
|