Permit Number | BLD01-01383 |
Status | Finaled |
Name |
WELLS FARGO
|
Site Address |
3295 W ELDER ST
|
Project Name | |
Customer Number | |
ePlanReview | No |
Description |
(WELLS FARGO) To enlarge the telecom rooms on the 2nd, 3rd and 4th floors from 57 sq.ft. to 106 sq.ft. per approved plans on file. Work to include, constructing approximately 19 lf of one hour rated partitions adjacent to corridor, installation of one 20 minute fire rated door assembly. NOTE: This building is fully fire sprinklered for 1-hr. fire resistive substitution. Any alterations or modifications to the fire sprinkler system shall be per NFPA #13 as regulated by the fire department. (P.C.#0438-01) *RmH* **(MODIFICATION TO CONSTRUCTION REQUIREMENTS)** DURING THE INSPECTION FOR THIS PROJECT THE INSPECTOR OBSERVED THAT THE CORRIDOR DID NOT MEET THE ONE-HOUR FIRE-RESISTIVE CONSTRUCTION REQUIREMENTS, (NO RATED CEILING ASSEMBLYS), THE ARCHITECT HAS RE ANALYIZED THE EXISTING TENANT EXITING REQUIREMENTS ON THE 2ND THRU 4TH FLOORS AND HAS PROPOSED THAT EACH FLOOR HAS LESS THAN 100 OCCUPANTS AND THE OFFICE BUILDING IS FULLY FIRE SPRINKLERED. THIS MEETS THE REQUIREMENT IN UBC SECTION 1004.3.4.3 EX: #5 FOR CONSTRUCTION OF A NONRATED CORRIDOR. *(RmH)* 7/30/01
|