BLD-Final | 5/16/2002 | 5/17/2002 | 5/17/2002 | A | PASS |
Steven Webb
|
|
|
C. of C. #22401 issued. 5/17/2002 11:35:49 AM
|
BLD-Final | 5/13/2002 | 5/14/2002 | 5/14/2002 | P | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 05/13/2002 at 15:38:14. Contact: ###-####. C/N on site 5/14/2002 3:01:28 PM
|
BLD-Framing/Rough-in | 2/19/2002 | 2/20/2002 | 2/20/2002 | A | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 02/19/2002 at 20:25:38. Contact: ###-####. shear ok at garage,also insulation inspection done by 420. 2/20/2002 1:41:30 PM
|
BLD-Framing/Rough-in | 2/15/2002 | 2/19/2002 | 2/18/2002 | A | CANC |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 02/15/2002 at 16:18:56. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on 02/18/2002 at 20:50:49.
|
BLD-Framing/Rough-in | 2/10/2002 | 2/11/2002 | 2/11/2002 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 02/10/2002 at 20:24:21. Contact: ###-####. Eng.(John David Mortin-PE) provided documents/repairs on overheight walls, hd mislocated, field changes to eng. also--shear panels re-nailing done--garage shear per plans will be 5/8" both sides, blocked and fastened 4" field and edges. Tom Cory--oked damaged I-joist--Truss B1GR ok per R. Anderson Bok to insulate and ok to side. 2/11/2002 1:48:52 PM
|
BLD-Framing/Rough-in | 2/6/2002 | 2/7/2002 | 2/7/2002 | A | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 02/06/2002 at 17:09:45. Contact: ###-####. 2--C/N posted--one for shear and one for framing--do not insulate and do not side. 2/7/2002 10:02:15 AM
|
BLD-Aging Inspection | 1/28/2002 | 1/28/2002 | 1/28/2002 | | PASS |
Steven Webb
|
|
|
permit active 1/28/2002 7:53:49 AM
|
BLD-Footing | 11/21/2001 | 11/26/2001 | 11/26/2001 | A | PART |
Steven Webb
|
|
|
###-#### DAVE wip 11/26/2001 9:23:11 AM
|