BLD-Aging Inspection | 2/13/2004 | 2/13/2004 | 2/13/2004 | | DONE |
Dave Hannah
|
|
|
|
BLD-Final | 10/22/2002 | 10/22/2002 | 10/22/2002 | P | PASS |
Jim Sly
|
|
|
###-#### NICK OK for Perm. Occ. 10/22/2002 1:51:29 PM
|
FIRE-Final Inspection | 10/21/2002 | 10/22/2002 | 10/22/2002 | A | PASS |
Rick Jackson
|
|
|
will have address and "Door to remain unlocked..." sign on main lobby door for structural inspector 10/22/2002 9:17:46 AM
|
Code Occupancy Approval | 10/8/2002 | 10/8/2002 | 10/8/2002 | P | PASS |
Wm. Michael Meloy
|
|
|
Approved 10/8/2002 12:16:43 PM
|
FIRE-Final Inspection | 10/8/2002 | 10/8/2002 | 10/8/2002 | P | FAIL |
Rick Jackson
|
|
|
nick; Phone #: ###-#### Internet Inspection Request from: Darla Downs need"Park only in marked stalls" signs at entrances; need address clarified - TI has 490 Mill Station; door to remain unlocked sign above main entrance 10/8/2002 3:25:58 PM
|
BLD-Framing/Rough-in | 7/3/2002 | 7/3/2002 | 7/3/2002 | P | PART |
Russ Owen
|
|
|
NICK ###-#### -FR. interior shear ok. 7/3/2002 2:20:25 PM
|
BLD-Final | 6/19/2002 | 6/20/2002 | 6/20/2002 | A | CANC |
Tom Arcoraci
|
|
|
NICK ###-####
|
BLD-Framing/Rough-in | 6/20/2002 | 6/20/2002 | 6/20/2002 | A | PART |
Tom Arcoraci
|
|
|
Added by Inspector: 408 On 6/20/2002 9:37:03 AM ok for cover needs int shear insp
|
BLD-Framing/Rough-in | 6/17/2002 | 6/17/2002 | 6/17/2002 | P | FAIL |
Steven Webb
|
|
|
nick ###-####- fr C/N issued--Framing for skylight area only--missing LTP4 hardware per plans on S-4. 6/17/2002 2:51:39 PM
|
BLD-Foundation | 6/14/2002 | 6/14/2002 | 6/14/2002 | P | CANC |
Jim Storey
|
|
|
NICK ###-#### wrong type of insp requsted. 6/14/2002 3:25:19 PM
|
BLD-Framing/Rough-in | 6/14/2002 | 6/14/2002 | 6/14/2002 | P | PART |
Jim Storey
|
|
|
interior holddowns in place with nut.
|
BLD-Framing/Rough-in | 6/4/2002 | 6/5/2002 | 6/5/2002 | A | PART |
Steven Webb
|
|
|
44-2334 Part interior shear--ok to sheetrock elec. room and draft stop in attic. 6/5/2002 11:15:33 AM
|
BLD-Framing/Rough-in | 5/23/2002 | 5/24/2002 | 5/24/2002 | A | PART |
Steven Webb
|
|
|
###-#### Ext. shear--ok to side. 5/24/2002 9:46:05 AM
|
BLD-Framing/Rough-in | 5/22/2002 | 5/23/2002 | 5/23/2002 | A | FAIL |
Steven Webb
|
|
|
roof nailing insp nick -###-#### SHEAR--C/N posted in job trailer. 5/23/2002 9:59:11 AM
|
BLD-Foundation | 4/16/2002 | 4/17/2002 | 4/17/2002 | A | PART |
Steven Webb
|
|
|
###-#### NICK Appears ok--special inspection. 4/17/2002 11:04:15 AM
|
BLD-Footing | 4/10/2002 | 4/11/2002 | 4/11/2002 | A | PASS |
Steven Webb
|
|
|
###-#### nick Per plans-Building outside footing--not interior or columns. 4/11/2002 11:39:12 AM
|