Permit Information
Permit NumberBLD01-03228
StatusFinaled
Name VFP VC
Site Address 3548 S FINDLEY AVE
Project NameFAMILY CENTER
Customer Number 
ePlanReviewNo
Description
FAMILY CENTER RETAIL SHELL BUILDING FOR PAD P2 - TO CONSRUCT A NEW 18,650 SQUARE FOOT, ONE STORY, MULTI-TENANT SHELL BUILDING AND RELATED SITE IMPROVEMENTS. THIS BUILDING IS BEING CONSTRUCTED OF CONCRETE FOUNDATION AND SLAB FLOORS, MASONRY EXTERIOR WALLS, STEEL JOIST AND METAL ROOF WITH SOME WOOD FRAMED OVERBUILD. THIS BUILDING IS FULLY FIRE SPRINKLED. THE SPRINKLERS ARE BEING USED FOR ALLOWABLE AREA INCREASE. THIS IS A SHELL PERMIT ONLY, NO OCCUPANCY IS ALLOWED UNDER THIS PERMIT. SEPARATE TENANT IMPROVEMENT PERMITS ARE REQUIRED TO FINISH EACH TENANT SPACE FOR OCCUPANCY. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED COMMENT LIST. THIS BUILDING IS BEING CONSIDERED AND REVIEWED AS ONE BUILDING WITH THE EXISTING BUILDING ON THE PAD TO THE SOUTH. THE TWO BUILDINGS TOGETHER HAVE A TOTAL AREA OF APPROXIMATELY 37,650 SQUARE FEET(INCLUDING THE TRIANGLE TRELLIS AREA). BOTH BUILDING ARE TYPE V-N CONSTRUCTION AND FULLY FIRE SPRINKLED. JCM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection12/16/200312/16/200312/16/2003 DONE
DetailsJim Storey
7/26/02 310 12/16/2003 9:34:21 AM
BLD-Final7/25/20027/26/20027/26/2002APASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 07/25/2002 at 08:08:02. Contact: ###-####.final ok l/c. 7/26/2002 1:10:39 PM
FIRE-Final Inspection7/26/20027/26/20027/26/2002PPASS
DetailsRick Jackson
Code Occupancy Approval7/23/20027/23/20027/23/2002PPASS
DetailsWm. Michael Meloy
Approved for shell only. 7/23/2002 2:42:00 PM
BLD-Wall cover6/4/20026/5/20026/5/2002APASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 06/04/2002 at 10:48:09. Contact: ###-####.reports justifing iuses signed off by engineer of record. 6/5/2002 9:48:30 AM
BLD-Wall cover5/28/20025/28/20025/28/2002PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 05/28/2002 at 08:25:31. Contact: ###-####. OK to cover Exterior walls (Pending Electr, Plumbing approval) and (1) side Tenant Dem wall. 5/28/2002 3:22:36 PM
BLD-Other5/22/20025/23/20025/23/2002AFAIL
DetailsJim Storey
Scheduled by a contractor via Hello! on 05/22/2002 at 12:04:34. Contact: ###-####. perimotor welding not full width of inbed/ engineered colm to rebar not welded with proper rod and missing pass under bar to colm. to be resolved with special insp and engineer pending reports. 5/23/2002 3:54:07 PM
BLD-Other5/7/20025/8/20025/8/2002APASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 05/07/2002 at 15:01:36. Contact: ###-####.
BLD-Other5/7/20025/8/20025/8/2002PPASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 05/07/2002 at 15:02:18. Contact: ###-####. walls toped out si pending. 5/8/2002 4:52:23 PM
BLD-Foundation3/21/20023/22/20023/22/2002APART
DetailsJim Sly
Scheduled by a contractor via Hello! on 03/21/2002 at 12:20:10. Contact: ###-####. Rebar appears OK but, Appr plan Req. special insp reinforcem. Need: A- Letter from Eng. delete special insp. OR B- Approval of modified plan. OR C- Have special insp agency insp rebar prior to pour. Spec insp Req Welding, Masonry, Epoxy. 3/22/2002 10:18:35 AM 3/22/2002 10:20:19 AM
BLD-Footing3/18/20023/19/20023/19/2002ANR
DetailsJim Storey
ft insp dale- ###-#### bad weather conitions ft not covered. recall. 3/19/2002 2:16:20 PM
BLD-Footing3/12/20023/13/20023/13/2002PPART
DetailsJim Storey
Scheduled by a contractor via Hello! on 03/12/2002 at 12:39:03. Contact: ###-####. north ft and 50% ok east ft rebar ok. 3/13/2002 4:31:06 PM
BLD-Other5/7/20023/25/20003/25/2000APART
DetailsJim Storey
massonary insp. top out south wall ok pending special insp.