Permit NumberBLD02-00563
StatusExpired
Name GQ CONSTRUCTION
Site Address 1832 S LATAH ST
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 1306 sq. ft. two story single family dwelling with a 90 sq. ft. covered front porch and a 150 sq. ft. concrete patio at rear of structure per approved plans, all engineering and attached requirement lists. (1st floor 646 sq. ft.)(2nd floor 660 sq. ft.). Scope of work to include a 418 sq. ft. detached two car garage and concrete apron off alley. MASTER FILE #02-03-001 PC #129 DJO
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/9/200212/10/200212/10/2002ANR
DetailsTom Arcoraci
BLD-Final10/25/200210/25/200210/25/2002PFAIL
DetailsJim Sly
###-#### No approved plans. 10/25/2002 1:40:20 PM
BLD-Final10/23/200210/24/200210/24/2002AFAIL
DetailsJim Storey
no access/ need approved plan/ 10/24/2002 9:49:36 AM
BLD-Final10/22/200210/23/200210/23/2002ACANC
DetailsJim Storey
Phone #: ###-#### Internet Inspection Request from: Rita DeYoungout of time 10/23/2002 5:01:48 PM
BLD-Energy code compliance5/9/20025/9/20025/9/2002APASS
DetailsDave Hannah
Added by Inspector: 425 On 5/9/2002 10:20:26 AM
BLD-Framing/Rough-in5/8/20025/9/20025/9/2002ADONE
DetailsDave Hannah
###-####
BLD-Framing/Rough-in5/3/20025/6/20025/6/2002ANR
DetailsTom Arcoraci
###-####
BLD-Framing/Rough-in5/6/20025/6/20025/6/2002PPASS
DetailsTom Arcoraci
TRAVIS ###-####
BLD-Framing/Rough-in5/1/20025/1/20025/1/2002PFAIL
DetailsTom Arcoraci
###-#### TRAVIS cn posted 5/1/2002 3:55:21 PM
BLD-Framing/Rough-in4/26/20024/29/20024/29/2002APASS
DetailsJim Storey
###-#### traviss sidding ok for cover c/n made ok 4/29/2002 8:28:39 AM
BLD-Framing/Rough-in4/25/20024/26/20024/26/2002AFAIL
DetailsRuss Owen
SHEER WALL TRAVIS ###-#### Garage needs hold downs and nailing, house needs exterior straps as per tall wall engineering, House has ok to side sticker in window. Contractor notified of the above. 4/26/2002 11:43:22 AM
BLD-Framing/Rough-in4/26/20024/26/20024/26/2002PFAIL
DetailsRuss Owen
SHEER NAIL ###-#### TRAVIS Note garage not complete, Wanted to finish siding at house only c/n posted for house only . Contractor not on site at this time. 4/26/2002 2:38:35 PM 4/26/2002 2:41:51 PM
BLD-Framing/Rough-in4/24/20024/24/20024/24/2002PPART
DetailsJim Storey
shear wall travis ###-#### tall wall engineering/grage nailling/hold downs 4/24/2002 3:52:15 PM
BLD-Framing/Rough-in4/22/20024/23/20024/23/2002AFAIL
DetailsJim Storey
1. ALTERNATE WALL PANEL FOR TWO STORY - Any braced wall panel, in the first story of two-story builings, may be replaced by an alternate braced wall panel having the following features: (1) each panel shall have a length of not less than 2 feet 8 inches and a height of not more than 10 feet, (2) each panel shall be sheathed on both faces with 3/8-inch-minimum-thichness plywood sheathing nailed with 8d common or galvanized box nails spaced 6 inches on center at the edges and 12 inches at intermediate supports, (3) all plywood edges are blocked, (4) three 1/2 inch anchor bolts with properly sized nuts and washers and imbedded at least 7 inches into the concrete are provided at panel one-fifth points, (5) each panel end stud shall have a tie-down device, installed in accordance with the manufacturer's recommendations, fastened to the foundation and capable of providing an approved uplift capacity of not less than 3,000 pounds, (6) the panels shall be supported directly on a foundation or on floor framing supported directly on a foundation which is continuous across the entire length of the braced wall line, and (6) the foundation is reinforced with not less than one No. 4 bar top and bottom. (1997 UBC 2320.11.4)

2. BRACED WALL PANELS - Braced wall lines shall consist of braced wall panels which are in line or offset from each other by not more than 4 feet. Braced wall panels shall start at not more than 8 feet from each end of a braced wall line. All braced wall panels shall be clearly indicated on the plans. (1997 UBC 2320.11.3) Braced wall lines are considered to end at perpendicular braced wall lines. Braced wall panels shall meet the requirements for location, type, and amount of bracing specified in 1997 UBC Table 23-IV-C-1. The construction of braced wall panels shall be by one of the methods listed in 1997 UBC 2320.11.3. Diagonal braces are not allowed in Seismic Zone "2B". (1997 UBC Table 23-IV-C-1)
BLD-Footing3/28/20023/29/20023/29/2002APART
DetailsJim Storey
WES ###-#### FT wip 3/29/2002 9:56:47 AM