BLD-Final | 4/2/2003 | 4/2/2003 | 4/2/2003 | P | PASS |
Tom Arcoraci
|
|
|
###-#### please issue letter of compliance at office 4/3/2003 9:27:33 AM
|
BLD-Final | 12/9/2002 | 12/10/2002 | 12/10/2002 | A | NR |
Tom Arcoraci
|
|
|
Phone #: ###-#### Internet Inspection Request from: Amy Lawson
|
BLD-Final | 10/23/2002 | 10/24/2002 | 10/24/2002 | A | FAIL |
Jim Storey
|
|
|
foudation vents missing/no access 10/24/2002 9:36:48 AM
|
BLD-Final | 10/22/2002 | 10/23/2002 | 10/23/2002 | A | CANC |
Jim Storey
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung out of time. 10/23/2002 5:02:33 PM
|
BLD-Energy code compliance | 5/9/2002 | 5/9/2002 | 5/9/2002 | A | PASS |
Dave Hannah
|
|
|
Added by Inspector: 425 On 5/9/2002 10:19:50 AM
|
BLD-Framing/Rough-in | 5/8/2002 | 5/9/2002 | 5/9/2002 | A | DONE |
Dave Hannah
|
|
|
###-####
|
BLD-Framing/Rough-in | 5/3/2002 | 5/6/2002 | 5/6/2002 | A | NR |
Tom Arcoraci
|
|
|
###-#### needs 2 full lenth studs on outside straps on 1st floor per eng 5/6/2002 10:40:34 AM
|
BLD-Framing/Rough-in | 5/6/2002 | 5/6/2002 | 5/6/2002 | P | PASS |
Tom Arcoraci
|
|
|
TRAVIS ###-####
|
BLD-Framing/Rough-in | 5/1/2002 | 5/1/2002 | 5/1/2002 | P | FAIL |
Tom Arcoraci
|
|
|
###-#### TRAVIS cn posted 5/1/2002 3:55:12 PM
|
BLD-Framing/Rough-in | 4/26/2002 | 4/29/2002 | 4/29/2002 | A | PASS |
Jim Storey
|
|
|
###-#### travis c/n made ok for sidding cover. 4/29/2002 8:28:00 AM
|
BLD-Framing/Rough-in | 4/25/2002 | 4/26/2002 | 4/26/2002 | A | FAIL |
Russ Owen
|
|
|
SHEER WALL TRAVIS ###-#### Garage needs hold downs and nailing, House needs exterior straps at stairs as per tall wall engineering. House has ok to side sticker in window. Contractor at site notified of this Will recall. 4/26/2002 11:42:10 AM
|
BLD-Framing/Rough-in | 4/26/2002 | 4/26/2002 | 4/26/2002 | P | FAIL |
Russ Owen
|
|
|
SHEER NAIL ###-#### TRAVIS : Garage also not done, contractor wanted to complete siding at house, c/n posted for house only contractor. note: contractor not on site at this time.. 4/26/2002 2:36:38 PM 4/26/2002 2:39:20 PM 4/26/2002 2:41:25 PM
|
BLD-Framing/Rough-in | 4/24/2002 | 4/24/2002 | 4/24/2002 | P | PART |
Jim Storey
|
|
|
travis ###-#### shear wall need engineering for tall wall and grage nailling and hardware 4/24/2002 3:51:38 PM
|
BLD-Framing/Rough-in | 4/22/2002 | 4/23/2002 | 4/23/2002 | A | FAIL |
Jim Storey
|
|
|
1. ALTERNATE WALL PANEL FOR TWO STORY - Any braced wall panel, in the first story of two-story builings, may be replaced by an alternate braced wall panel having the following features: (1) each panel shall have a length of not less than 2 feet 8 inches and a height of not more than 10 feet, (2) each panel shall be sheathed on both faces with 3/8-inch-minimum-thichness plywood sheathing nailed with 8d common or galvanized box nails spaced 6 inches on center at the edges and 12 inches at intermediate supports, (3) all plywood edges are blocked, (4) three 1/2 inch anchor bolts with properly sized nuts and washers and imbedded at least 7 inches into the concrete are provided at panel one-fifth points, (5) each panel end stud shall have a tie-down device, installed in accordance with the manufacturer's recommendations, fastened to the foundation and capable of providing an approved uplift capacity of not less than 3,000 pounds, (6) the panels shall be supported directly on a foundation or on floor framing supported directly on a foundation which is continuous across the entire length of the braced wall line, and (6) the foundation is reinforced with not less than one No. 4 bar top and bottom. (1997 UBC 2320.11.4)
2. BRACED WALL PANELS - Braced wall lines shall consist of braced wall panels which are in line or offset from each other by not more than 4 feet. Braced wall panels shall start at not more than 8 feet from each end of a braced wall line. All braced wall panels shall be clearly indicated on the plans. (1997 UBC 2320.11.3) Braced wall lines are considered to end at perpendicular braced wall lines. Braced wall panels shall meet the requirements for location, type, and amount of bracing specified in 1997 UBC Table 23-IV-C-1. The construction of braced wall panels shall be by one of the methods listed in 1997 UBC 2320.11.3. Diagonal braces are not allowed in Seismic Zone "2B". (1997 UBC Table 23-IV-C-1)
|
BLD-Footing | 3/28/2002 | 3/29/2002 | 3/29/2002 | A | PART |
Jim Storey
|
|
|
WES ###-#### FT wip 3/29/2002 9:56:36 AM
|