BLD-Final | 7/29/2002 | 7/30/2002 | 7/30/2002 | A | PASS |
Tony Young
|
|
|
###-#### gary hand rail inspect
|
BLD-Final | 7/26/2002 | 7/29/2002 | 7/29/2002 | P | FAIL |
Tom Arcoraci
|
|
|
###-#### needs handrail at new rear porch then ok for lc 7/29/2002 2:39:11 PM
|
BLD-Conference | 5/13/2002 | 5/13/2002 | 5/13/2002 | A | PASS |
Carl Dependahl
|
|
|
w/ bldr re insul.
|
BLD-Conference | 5/13/2002 | 5/13/2002 | 5/13/2002 | A | PASS |
Carl Dependahl
|
|
|
w/ bldr...frame ok to cover per 415. 5/13/2002 4:21:40 PM
|
BLD-Energy code compliance | 5/6/2002 | 5/6/2002 | 5/13/2002 | P | PART |
Carl Dependahl
|
|
|
###-#### JEFF...previously ok'd by 415??? 5/13/2002 10:05:55 AM
|
BLD-Framing/Rough-in | 5/6/2002 | 5/7/2002 | 5/7/2002 | A | PASS |
Tony Young
|
|
|
|
BLD-Framing/Rough-in | 5/3/2002 | 5/6/2002 | 5/6/2002 | A | PASS |
Tony Young
|
|
|
###-#### JEFF
|
BLD-Framing/Rough-in | 5/2/2002 | 5/2/2002 | 5/2/2002 | P | NR |
Jim Storey
|
|
|
1. need ele insp./ nail joist hangers
2. umc 603.2 replace exsusted duct.
3. tie south bearing wall to exsting bldg.
4. TRUSS ENGINEERING - The design and fabrication of metal plate connected wood trusses shall be in accordance with ANSI/TPI 1-1995. (1997 UBC 2321.1) Each truss shall be legibly branded, marked or otherwise have permanently affixed thereto the following information located within 2 feet of the center of the span on the face of the bottom chord: (1) Identity of the company manufacturing the truss. (2) The design load. (3) The spacing of trusses. (1997 UBC 2321.4) Provide truss specifications to the Building Inspector prior to inspection.
5. ATTIC ACCESS - An attic access opening shall be provided to attics of buildings with combustible ceiling or roof construction. The opening shall be located in a corridor, hallway, or other readily accessible location. Attics with a maximum vertical height of less than 30 inches need not be provided with access openings. The opening shall not be less than 22 inches by 30 inches. A minimum clear headroom of at least 30 inches shall be provided at or above the access opening. 1994 UBC 1505.1
6. calk and seal to meet boise city engery code.
|
BLD-Framing/Rough-in | 4/30/2002 | 5/1/2002 | 5/1/2002 | A | PART |
Dave Hannah
|
|
|
shear jeff -###-#### ext ok to cover 5/1/2002 10:41:32 AM
|
BLD-Foundation | 3/27/2002 | 3/28/2002 | 3/28/2002 | A | PASS |
Carl Dependahl
|
|
|
JEFF ###-#### chk bsmt ftg at frame 3/28/2002 10:48:17 AM
|
BLD-Footing | 3/26/2002 | 3/27/2002 | 3/27/2002 | A | PART |
Carl Dependahl
|
|
|
###-#### JEFF; ext ftgs ok, chk bsmt int ftg at frame insp or? see plan. 3/27/2002 10:53:59 AM
|