Permit Information
Permit NumberBLD03-00568
StatusFinaled
Name CORPUS CHRISTI SERVICE CENTER
Site Address 525 N AMERICANA BLVD
Project Name 
Customer Number 
ePlanReviewNo
Description
(CORPUS CHRISTI SERVICE CENTER) Remodel to an existing 2,500 sq.ft. building changing occupancy to an assembly social service day activity center per approved plans and CZC03-00030. Work to include some structural demolition work including removing a section of CMU interior bearing wall, new glulam beam installation with new 6x6 support posts and connectors, two new structural openings in existing CMU interior wall, CMU exterior wall infill in former window and overhead door openings, concrete slab work, new CMU walls to enclose a new courtyard at rear of building, some new interior walls, some new interior doors, new exterior windows and doors, interior finish, new suspended ceiling, upgrading an existing restroom to current accessibility standards, two new multiple fixture accessible restrooms with accessible showers, providing accessible hardware on all doors, constructing a one-hour rated equipment room with 45 minute rated door per architect, exterior site/parking lot modifications, mechanical work including replacing a unit with a new HVAC rooftop unit, plumbing work, and electrical work. Special Inspection is required for Hilti Hit HY-150 Adhesive Anchor installations. North and South exterior walls of this building are right on property lines and are existing one-hour rated walls with no openings and 30" minimum parapets. Nonseparated uses per IBC Section 302.3.2. A Certificate of Occupancy is to be issued when completed and approved. An interior non-bearing demolition permit was done under a separate permit, BLD03-00598. NOTE: This building is NOT fire sprinklered. (PC#0143-03) JCB
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 12/6/200312/6/2003 DONE
Details
BLD-Final12/2/200312/2/200312/2/2003PPASS
DetailsTom Arcoraci
roger; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok for perm occ 12/2/2003 2:12:43 PM
BLD-Final11/26/200311/28/200311/28/2003APASS
DetailsTom Arcoraci
done???-earl ###-#### ok for perm when others sign perm occ 11/28/2003 9:15:38 AM
BLD-Final11/28/200311/28/200311/28/2003PPASS
DetailsTom Arcoraci
Larry; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
BLD-Final11/25/200311/25/200311/26/2003PDONE
Henry, ###-####
FIRE-Final Inspection11/14/200311/17/200311/17/2003PPASS
DetailsRick Jackson
Earl; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIRE-Final Inspection11/12/200311/13/200311/13/2003AFAIL
DetailsTroy Cobbley
provide address per review note #4, tag fire extinguishers per review note #5, provide approved door hardware per scope of work comments and review note #6, repair exit signs, test duct smoke detector (contractor said the new unit had one, plans say unit is only 2,000 cfm), post occupancy load sign as discussed, provide closure on the furnace room door. 11/13/2003 10:36:19 AM
BLD-Final11/10/200311/12/200311/12/2003ACANC
DetailsRick Jackson
Earl; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes this was scheduled for Dave Hannah by mistake as they need a fire final; rescheduled for 11/13 11/12/2003 4:00:15 PM
BLD-Final10/28/200310/28/200310/28/2003PNR
DetailsTom Arcoraci
earl ###-####
BLD-Framing/Rough-in10/23/200310/24/200310/24/2003APART
DetailsDave Hannah
earl; Phone #: ###-#### Internet Inspection Request from: Annette Moore ceiling grid field ok but still needs to add perm wires and spacer bars 10/24/2003 10:10:02 AM
BLD-Other10/21/200310/21/200310/21/2003PNR
DetailsDave Hannah
Ceiling grid inspection//earl; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Framing/Rough-in7/24/20037/24/20037/24/2003PPASS
DetailsJim Storey
earl; Phone #: ###-#### Internet Inspection Request from: Annette Moore c/n made ok. 7/24/2003 2:07:18 PM
BLD-Framing/Rough-in7/22/20037/23/20037/23/2003PFAIL
DetailsCarl Dependahl
earl; Phone #: ###-#### Internet Inspection Request from: Annette Moore...c/n, fireblocks....remove existing insul. face paper. 7/23/2003 1:21:52 PM
BLD-Conference6/24/20036/24/20036/24/2003PNR
DetailsCarl Dependahl
Aging follow up...unable to contact 6/24/2003 5:08:35 PM
BLD-Footing5/30/20036/2/20036/2/2003APASS
DetailsTom Arcoraci
EARL; Phone #: ###-#### Internet Inspection Request from: Annette Moore 6/2/2003 8:54:53 AM footing ok for in fill 6/2/2003 11:09:58 AM