Permit Information
Permit NumberBLD03-02848
StatusFinaled
Name AMERICAN RED CROSS
Site Address 404 S 8TH ST Unit: 232
Project Name8TH STREET MARKEPLACE
Customer Number 
ePlanReviewNo
Description
(AMERICAN RED CROSS - 8TH STREET MARKETPLACE - STE 232) This building is fire sprinklered to substitute for 1-hr fire-resistance-rated construction. To remodel a 5,454 square foot office tenant space located on the 2nd floor of "Building 404" in the "8th Street Marketplace". Existing restrooms that are NOT accessible to the disabled are being demolished. An existing stairway that connects the 2nd floor with the 1st floor is being removed. Work is to include interior nonbearing walls, 3-hr wall infills, a floor infill, a relocated security grill, a ramp accessible to the disabled, interior stairways, and finishes all per the approved drawings and the plan review report on file. The location of fire sprinkler heads shall comply with NFPA 13-1999 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/19/20041/20/20041/20/2004APASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 1/19/2004 at 3:14:40 PM. Contact: ###-####. ok for perm occ 1/20/2004 2:10:22 PM
FIRE-Final Inspection1/19/20041/20/20041/20/2004APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 1/19/2004 at 3:15:33 PM. Contact: ###-####. The fire sprinkler tamper valves are not supervised by the fire alarm panel; the GC will have them added with fire alarm submittals under BLD03-02412 1/20/2004 3:11:22 PM
Permanent Occupancy 1/20/20041/20/2004 DONE
Details
BLD-Final1/16/20041/16/20041/16/2004PFAIL
DetailsDave Hannah
Scheduled by a contractor via Hello! on 1/16/2004 at 7:08:53 AM. Contact: ###-####.
FIRE-Final Inspection1/16/20041/16/20041/16/2004AFAIL
DetailsRick Jackson
Scheduled by a contractor via Hello! on 1/16/2004 at 7:20:15 AM. Contact: ###-####. doors with mag hold opens require smoke detectors for door release; penetrations in three hour wall require firestopping; exit sign needed as shown on plans; door to east stair to have passage set; fire sprinklers within 6 ft of each other by west exit; smoke detector required above FACP 1/16/2004 3:01:51 PM
BLD-Framing/Rough-in12/22/200312/22/200312/22/2003PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 12/22/2003 at 9:46:53 AM. Contact: ###-####.