Permit Information
Permit NumberBLD04-01984
StatusFinaled
Name VILLA PIZZA
Site Address 350 N MILWAUKEE ST Unit: 2024
Project NameBTS - #2024
Customer Number 
ePlanReviewNo
Description
(VILLA PIZZA)(BOISE TOWNE SQUARE-SPACE 2024) To remodel a 742 sq.ft. space for new food service tenant on the upper level per approved plans. This space was previously occupied by "Marios Piaza" this is a food service kitchen for the food court, work will include, reconstruction of the face of the bulkhead the bulkhead is to remain noncombustible, with a 5/8 type x gypboard attached to framing members, a new type one hood system is being installed with a one hour duct wrap, a new service countere is being installed, some additional lighting fixtures are being installed, the existing coolers are being reused. Miscelaneous related interior finishes. This building is fully fire sprinklered and contains a smoke evacuation system, any modifications to the sprinkler system shall be per NFPA #13 and the smoke evacuation system shall remain functional as installed under the 1985 UBC. (pc#561-04)rmh
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/23/200411/24/200411/24/2004APASS
DetailsLane Manuel
Scheduled by a contractor via Hello! on 11/23/2004 at 3:02:01 PM. Contact: ###-####.
Permanent Occupancy 11/24/200411/24/2004 DONE
Details
BLD-Final11/23/200411/23/200411/23/2004PCANC
DetailsLane Manuel
Scheduled by a contractor via Hello! on 11/23/2004 at 8:43:39 AM. Contact: ###-####.
needs mech., and plumbing insp. final, prior to bldg final 11/23/2004 3:49:51 PM
FIRE-Final Inspection11/22/200411/22/200411/22/2004APASS
DetailsRick Jackson
Fire life safety final okay 11/22/2004 9:44:36 AM
BLD-Final11/18/200411/19/200411/19/2004PNR
DetailsLane Manuel
Scheduled by a contractor via Hello! on 11/18/2004 at 10:25:41 AM. Contact: ###-####.
need final insp's by plumbing, mech., and fire prior to bldg final. 11/19/2004 3:02:16 PM
FIRE-Final Inspection11/18/200411/19/200411/19/2004AFAIL
DetailsTroy Cobbley
Need to final fire alarm. Provide canopies for pendants and ceiling tile. Notified general contractor that he could not install manual flush bolt on the door the separates the counter from the kitchen 11/19/2004 2:00:14 PM
BLD-Framing/Rough-in11/1/200411/2/200411/2/2004APART
DetailsJim Sly
Randy-call 1/2 hr prior, in the food court; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner OK to cover interior wall (next to new type 1 hood). Advised Contr to fire caulk all new and old penitrations thru 1hr tenant walls. 11/2/2004 10:31:58 AM