Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberBLD05-01226
StatusFinaled
Name WESTROCK HOMES
Site Address 11143 W GREYLING DR
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 3820 sq.ft. One story w/ Basement Single family dwelling with (2358 sq.ft. Main Level / 1462 sq.ft. Basement) with a 634 sq.ft. Attached two car garage, a 340 sq.ft. Covered rear patio, and a 136 sq.ft. Covered front porch per approved plans and all red-lining. THE PERMIT HOLDER is responsible to comply with current wall bracing requirements adopted by the city of Boise. (SRZ)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/3/20063/6/20063/6/2006APASS
DetailsMike Jordan
Chris; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. egress ladders were installed.
DOC - Permit Finaled3/6/20063/6/20063/6/2006PPASS
DetailsMike Jordan
BLD-Final3/2/20063/3/20063/3/2006AFAIL
DetailsMike Jordan
Chris -- call 1st before inspection for lockbox code access; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Needs egress ladders in window wells at bedrooms.
BLD-Energy code compliance11/21/200511/21/200511/22/2005PPASS
DetailsMike Jordan
chris; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. Areas requiring fireblovking were batted.
BLD-Energy code compliance11/16/200511/17/200511/17/2005APASS
DetailsMike Jordan
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Energy code compliance11/16/200511/16/200511/16/2005PNR
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/16/2005 at 7:40:03 AM. Contact: ###-####.
BLD-Framing/Rough-in11/14/200511/15/200511/15/2005PFAIL
DetailsMike Jordan
Scheduled by a contractor via Hello! on 11/14/2005 at 1:34:28 PM. Contact: ###-####. Still need previously noted hangars. All other items on c/n are complete.
BLD-Framing/Rough-in11/10/200511/14/200511/14/2005AFAIL
DetailsMike Jordan
chris; Phone #: ###-#### Note: Please call 1/2 hr prior to inspection Internet Inspection Request from: Cathy Chiles. Provide tall wall engineering. Provide additional 2x6 studs at CG truss bearing. Provide strapping at top plates at bearing walls in basement. (either side of stairway) Complete lateral bracing at AR2 and CG trusses. Provide HGUS26-2 hangars at A3B and FG trusses as noted on truss engineering.
BLD-Framing/Rough-in11/9/200511/10/200511/10/2005PFAIL
DetailsMike Jordan
chris; Phone #: ###-#### Please call 1/2 hr priro to inspection Internet Inspection Request from: Cathy Chiles. No plans or truss engineering on site.
BLD-Framing/Rough-in11/7/200511/8/200511/8/2005PNR
DetailsMike Jordan
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs plumbing ri inspection. No plans or truss engineering on site.
BLD-Foundation8/1/20058/2/20058/2/2005APART
DetailsTom Arcoraci
logan; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Footing7/28/20057/28/20057/28/2005PPASS
DetailsTom Arcoraci
logan; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Footing7/27/20057/27/20057/27/2005PCANC
DetailsTom Arcoraci
logan; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Footing7/12/20057/13/20057/13/2005APASS
DetailsMike Jordan
donny; Phone #: ###-#### Internet Inspection Request from: Barbara Moore. Set backs approved per p&z. Reviewed engineering changing the #6 Vert. reinforcement to #4 reinforcement to 10 inch o.c.-ok to place conc.
BLD-Foundation7/8/20057/8/20057/8/2005PFAIL
DetailsDave Hannah
Scheduled by a contractor via Hello! on 7/8/2005 at 7:25:45 AM. Contact: ###-####. side setbacks wrong
BLD-Footing6/15/20056/15/20056/15/2005PPART
DetailsTom Arcoraci