BLD-Final | 4/27/2009 | 4/27/2009 | 4/28/2009 | P | DONE |
Tony Young
|
|
|
Jack- call for access Phone #: ###-####
|
BLD-Final | 4/24/2009 | 4/27/2009 | 4/27/2009 | A | PASS |
Tony Young
|
|
|
Jack- call for access Phone #: ###-####
|
DOC - Permit Finaled | 4/27/2009 | 4/27/2009 | 4/27/2009 | P | PASS |
Tony Young
|
|
|
c of o issued
|
BLD-Final | 3/25/2009 | 3/26/2009 | 3/26/2009 | A | FAIL |
Tony Young
|
|
|
Read your email for the garage I farwarded to you on 3-25-09 in the afternoon c/n posted,, 9 items,, c/n in kitchen,, need: sprinklers finaled,, fire caulk holes in garage,, verify elec permit covered whole house and not just 3 rooms per permit scope,, cut curb for driveway or justify with a letter of ok from ACHD,, make smoke detectors functional for testing,, install missing ponywall studs under floor,, clean debris out of crawl space,, seal exterior crawl vents where pipes go through,, Do we have the City reviewed plans?
|
BLD-Grading Inspection | 3/17/2009 | 3/17/2009 | 3/17/2009 | A | DONE |
Terry Records
|
|
|
Final grading and drainage approved
|
BLD-Energy code compliance | 8/18/2006 | 8/21/2006 | 8/21/2006 | P | PASS |
Jim Sly
|
|
|
john; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Framing/Rough-in | 8/18/2006 | 8/21/2006 | 8/21/2006 | P | PASS |
Jim Sly
|
|
|
john; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Framing/Rough-in | 8/9/2006 | 8/9/2006 | 8/9/2006 | P | FAIL |
Mike Jordan
|
|
|
john; Phone #: ###-#### Internet Inspection Request from: Barbara BuckleNeeds to install floor to floor straps and phd holdowns as noted on approved plans. shear nailing ok. ok to insul. c/n posted.
|
FIRE-Sprinkler Rough-in | 8/8/2006 | 8/8/2006 | 8/8/2006 | P | PASS |
Troy Cobbley
|
|
|
Sprinkler piping is ok to cover.
|
FIRE-Sprinkler Rough-in | 8/7/2006 | 8/7/2006 | 8/7/2006 | P | FAIL |
Troy Cobbley
|
|
|
Rough-in failed. Do not cover sprinklers.
|
BLD-Footing | 3/21/2006 | 3/21/2006 | 3/21/2006 | P | PASS |
Tony Young
|
|
|
Matt ph# ###-####
|
BLD-Footing | 3/20/2006 | 3/21/2006 | 3/21/2006 | A | NR |
Tony Young
|
|
|
MATT; Phone #: ###-####
|
BLD-Footing | 3/20/2006 | 3/20/2006 | 3/20/2006 | P | NR |
Tony Young
|
|
|
matt Note: if possible 1:00 please; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles put notes on other inspection,, rescheduled for am as requested
|
BLD-Footing | 3/20/2006 | 3/21/2006 | 3/20/2006 | A | NR |
Tony Young
|
|
|
Matt; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong need to get to grade,, string west line
|